10.07.2015 Views

Sigma-II Series SGM*H/SGDH USER'S MANUAL - Esco Drives ...

Sigma-II Series SGM*H/SGDH USER'S MANUAL - Esco Drives ...

Sigma-II Series SGM*H/SGDH USER'S MANUAL - Esco Drives ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

11 Appendix11.3.3 Monitor Modes11.4 Parameter Recording TableParameterNo.Use the following table for recording parameters.Note: Setting validation (“immediately” or “after restart”) for Pn10B and Pn110 differs depending on thedigit. The digits validated after restart are underlined in “Factory Setting” column.FactorySettingNameSettingValidationPn000 0000 Function Selection Basic Switches After restartPn001 0000 Function Selection Application After restartSwitches 1Pn002 0000 Function Selection Application After restartSwitches 2Pn003 0002 Function Selection Application After restartSwitches 3Pn004 0000 Reserved (Do not change) ImmediatelyPn005 0000 Reserved (Do not change) ImmediatelyPn100 40 Hz Speed Loop Gain ImmediatelyPn101 20.00 ms Speed Loop Integral Time Constant ImmediatelyPn102 40 /s Position Loop Gain ImmediatelyPn103 0% Moment of Inertia Ratio ImmediatelyPn104 40 Hz 2nd Speed Loop Gain ImmediatelyPn105 20.00 ms 2nd Loop Integral Time Constant ImmediatelyPn106 40 /s 2nd Position Loop Gain ImmediatelyPn107 0 min -1 Bias ImmediatelyPn108 7 referenceBias Width AdditionImmediatelyunitsPn109 0% Feed-forward ImmediatelyPn10A 0.00 ms Feed-forward Filter Time Constant ImmediatelyPn10B 0000 Gain-related Application Switches After restartPn10C 200% Mode Switch Torque Reference ImmediatelyPn10D 0 min -1 Mode Switch Speed Reference ImmediatelyPn10E 0 min -1 /s Mode Switch Acceleration ImmediatelyPn10F 0 referenceMode Switch Error PulseImmediatelyunitsPn110 0010 Online Autotuning Switches After restartPn111 100% Speed Feedback Compensation ImmediatelyPn112 100% Reserved (Do not change) ImmediatelyPn113 1000 Reserved (Do not change) ImmediatelyPn114 200 Reserved (Do not change) ImmediatelyPn115 32 Reserved (Do not change) ImmediatelyPn116 16 Reserved (Do not change) ImmediatelyPn117 100% Reserved (Do not change) ImmediatelyPn118 100% Reserved (Do not change) ImmediatelyPn119 50 /s Reserved (Do not change) ImmediatelyPn11A 1000% Reserved (Do not change) ImmediatelyPn11B 50 Hz Reserved (Do not change) ImmediatelyPn11C 70 Hz Reserved (Do not change) ImmediatelyPn11D 100% Reserved (Do not change) ImmediatelyPn11E 100% Reserved (Do not change) ImmediatelyPn11F 0 ms Reserved (Do not change) Immediately11-44

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!