11 Appendix11.3.2 List of ParametersParameterNo.Name Setting Range Unit FactorySettingSettingValidationPn50D Input Signal Selections 4 − − 8888 AfterrestartReferenceSection−n.4th 3rddigit digit2nddigit 1stdigit/ZCLAMP Signal Mapping (Zero clamp when ON (L-level))(Refer to "8.5.6 Using the Zero Clamp Function.")0 ON when CN1-40 input signal is ON (L-level).1 ON when CN1-41 input signal is ON (L-level).2 ON when CN1-42 input signal is ON (L-level).3 ON when CN1-43 input signal is ON (L-level).4 ON when CN1-44 input signal is ON (L-level).5 ON when CN1-45 input signal is ON (L-level).6 ON when CN1-46 input signal is ON (L-level).7 Sets signal ON.8 Sets signal OFF.9 ON when CN1-40 input signal is OFF (H-level).A ON when CN1-41 input signal is OFF (H-level).B ON when CN1-42 input signal is OFF (H-level).C ON when CN1-43 input signal is OFF (H-level).D ON when CN1-44 input signal is OFF (H-level).E ON when CN1-45 input signal is OFF (H-level).F ON when CN1-46 input signal is OFF (H-level)./INHIBIT Signal Mapping (Reference pulse inhibit when ON (L-level))(Refer to "8.6.7 Reference Pulse Inhibit Function (INHIBIT).")0 to F Same as /ZCLAMP/G-SEL Signal Mapping (Gain change when ON (L-level))(Refer to "9.4.9 Switching Gain Settings.")0 to F Same as /ZCLAMPReserved (Do not change)11-40