10.07.2015 Views

Sigma-II Series SGM*H/SGDH USER'S MANUAL - Esco Drives ...

Sigma-II Series SGM*H/SGDH USER'S MANUAL - Esco Drives ...

Sigma-II Series SGM*H/SGDH USER'S MANUAL - Esco Drives ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

11.3 List of ParametersParameterNo.Name Setting Range Unit FactorySettingSettingValidationPn50A Input Signal Selections 1 − − 2100 AfterrestartReferenceSection−n.4th 3rd 2nddigit digit digit1stdigitInput Signal Allocation Mode(Refer to "7.3.2 Input Circuit Signal Allocation.")0 Uses the sequence input signal terminals with standard allocation. ∗1 Changes the sequence input signal allocation for each signal./S-ON Signal MappingSignal Polarity: Normal; Servo ON when ON (L-level)Signal Polarity: Reverse; Servo ON when OFF (H-level)(Refer to "8.3.1 Setting the Servo ON Signal.")0 ON when CN1-40 input signal is ON (L-level).1 ON when CN1-41 input signal is ON (L-level).2 ON when CN1-42 input signal is ON (L-level).3 ON when CN1-43 input signal is ON (L-level).4 ON when CN1-44 input signal is ON (L-level).5 ON when CN1-45 input signal is ON (L-level).6 ON when CN1-46 input signal is ON (L-level).7 Sets signal ON.8 Sets signal OFF.9 OFF when CN1-40 input signal is OFF (H-level).A OFF when CN1-41 input signal is OFF (H-level).B OFF when CN1-42 input signal is OFF (H-level).C OFF when CN1-43 input signal is OFF (H-level).D OFF when CN1-44 input signal is OFF (H-level).E OFF when CN1-45 input signal is OFF (H-level).F OFF when CN1-46 input signal is OFF (H-level)./P-CON Signal Mapping (P control when ON (L-level))(Refer to "9.4.4 Proportional Control Operation (Proportional Operation Reference).")0 to F Same as /S-ONP-OT Signal Mapping (Overtravel when OFF (H-level))(Refer to "8.3.3 Setting the Overtravel Limit Function.")0 Forward run allowed when CN1-40 input signal is ON (L-level).1 Forward run allowed when CN1-41 input signal is ON (L-level).2 Forward run allowed when CN1-42 input signal is ON (L-level).3 Forward run allowed when CN1-43 input signal is ON (L-level).4 Forward run allowed when CN1-44 input signal is ON (L-level).5 Forward run allowed when CN1-45 input signal is ON (L-level).6 Forward run allowed when CN1-46 input signal is ON (L-level).7 Forward run prohibited.8 Forward run allowed.9 Forward run allowed when CN1-40 input signal is OFF (H-level).A Forward run allowed when CN1-41 input signal is OFF (H-level).B Forward run allowed when CN1-42 input signal is OFF (H-level).C Forward run allowed when CN1-43 input signal is OFF (H-level).D Forward run allowed when CN1-44 input signal is OFF (H-level).E Forward run allowed when CN1-45 input signal is OFF (H-level).F Forward run allowed when CN1-46 input signal is OFF (H-level).1111-37

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!