10.1 TroubleshootingSymptomServomotorOverheatedTable 10.8 Troubleshooting for Malfunction without Alarm Display (Cont’d)InspectionCorrective ActionsCause: Turn OFF the servo system before executing operations.Ambient temperature too high Measure servomotor ambient temperature. Reduce ambient temperature to 40°C (104 °F) max.Servomotor surface dirty Check visually. Clean dust and oil from servomotor surface.Overloaded Run under no load. Reconsider load and operation conditions or replace withlarger capacity servomotor.1010-21