10.07.2015 Views

Sigma-II Series SGM*H/SGDH USER'S MANUAL - Esco Drives ...

Sigma-II Series SGM*H/SGDH USER'S MANUAL - Esco Drives ...

Sigma-II Series SGM*H/SGDH USER'S MANUAL - Esco Drives ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

9 Adjustments9.4.10 Torque Reference Filter9.5 Analog MonitorSignals for analog voltage references can be monitored.To monitor analog signals, connect the analog monitor cable (JZSP-CA01 or DE9404559) to the connector CN5.The analog monitor signals can be selected by setting parameters Pn003.0 and Pn003.1.CN5SERVOPARK 200V<strong>SGDH</strong>-Ver.YASKAWAPOWERCable Type:JZSP-CA01or DE9404559BlackMODE/SETDATA/CN5BATTERYFor 30W to 5.0 kW SERVOPACKRedBlackWhiteFor 6.0 to 15.0 kW SERVOPACKPin Number Line Color Signal Name Monitoring Item with Factory Setting1 Red Analog monitor 2 Motor speed: 1 V/1000 min -12 White Analog monitor 1 Torque reference: 1 V/100% rated torque3, 4 Black (2 lines) GND (0 V) −9-28

Hooray! Your file is uploaded and ready to be published.

Saved successfully!