8.11 Other Output Signals8.11.4 Servo Ready (/S-RDY) OutputTypeSignalNameConnector PinNumberSettingMeaningOutput /S-RDY CN1-29, 30 ON (low level) Servo is ready.(Factory setting) OFF (high level) Servo is not ready.This signal indicates that the SERVOPACK received the servo ON signal and completed all preparations.It is output when there are no servo alarms and the main circuit power supply is turned ON.An added condition with absolute encoder specifications is that when the SEN signal is at high level, absolute data was outputto the host controller.The servo ready signal condition can also be checked on the digital operator. For details, refer to 7.1.4 Status Display and7.4.1 List of Monitor Modes.The /S-RDY signal can be allocated to another output terminal with parameter Pn50E. For details, refer to 7.3.3 Output CircuitSignal Allocation.88-79