8 Operation8.5.1 Setting Parameters8.5 Operating Using Speed Control with Analog Reference8.5.1 Setting ParametersParameterDescriptionPn000 n.0 Control mode selection: Speed control (analog reference) (factory setting)Pn300Speed Reference Input GainSpeed Position TorqueSetting Range Setting Unit Factory Setting Setting Validation1.50 to 3000(150 to 30.00 V/Rated speed)0.01 V/RatedspeedSets the analog voltage level for the speed reference (V-REF) necessary to operate theservomotor at the rated speed.• EXAMPLEPn300=600: 6-V input is equivalent to the rated speed of the servomotor(factory setting).Pn300=1000: 10-V input is equivalent to the rated speed of the servomotor.Pn300=200: 2-V input is equivalent to the rated speed of the servomotor.600 ImmediatelyReferenceSpeed(min -1)Set thisslope.ReferenceVoltage (V)8-38