8.4 Absolute EncodersStepDisplay after Digital PanelOperation Operator OperatorDescription1 Alarm generated2DSPLPress the DSPL/SET or MODE/SET Key to select the utility functionSETmode.(DSPL/SET Key)MODE/SET(MODE/SET Key)3 Press the UP or DOWN Key to select parameter Fn008.Note: The digit that can be set will blink.4 Press the DATA/ENTER Key once, or DATA/SHIFT Key forDATAENTERmore than one second.The display will be as shown at the left.(DATA/ENTER Key)DATA/(DATA/SHIFT Key)(Press at least 1 s.)5 Continue pressing the UP Key until PGCL5 is displayed.Note: If there is a mistake in the key operation, “nO_OP” willblink for about one second. The panel operator or digitaloperator will return to the utility function mode.6 Press the DSPL/SET or MODE/SET Key. This will clear theDSPLSETmultiturn data of the absolute encoder.MODE/SET(DSPL/SET Key) (MODE/SET Key) When completed, “donE” will blink for about one second.7After “donE” is displayed, “PGCL5” will be displayed again.About one second later8 Press the DATA/ENTER Key once, or DATA/SHIFT Key forDATAENTERmore than one second to return to the Fn008 display of the utilityfunction mode.(DATA/ENTER Key)DATA/(DATA/SHIFT Key)(Press at least 1 s.)9 Turn OFF the power, and then turn it ON again to make the setting valid.88-31