7.3 Operation in Parameter Setting Mode (Pn)EXAMPLE• Allocating Output SignalsThe procedure to replace Rotation Detection (/TGON) signal allocated to CN1-27 (28) with factory settingto “Invalid” and allocate Brake Interlock (/BK) signal to CN1-27 (28) is shown below.Pn50E:BeforeAfterStepDisplay afterOperationDigitalOperatorPanelOperatorDescription1 Press the DSPL/SET or MODE/SET Key to select theDSPLSET“value setting parameter” mode. If a parameter other than(DSPL/SET Key) MODE/SET Pn50E is displayed, press the UP or DOWN Key to select(MODE/SET Key)Pn50E.Note: The enabled digit blinks.2 Press the DATA/ENTER Key once, or DATA/SHIFT KeyDATAfor more than one second to display the current data ofENTERDATA/Pn50E.(DATA/ENTER Key) (DATA/SHIFT Key)(/TGON is allocated to CN1-27 (28).)3 Press the LEFT Key or RIGHT or DATA/SHIFT Key toselect the third digit from the right. Press the DOWN KeyDATA/to set “0.”(DATA/SHIFT Key)(Sets /TGON “Invalid.”)4 Press the DATA/ENTER Key once, or DATA/SHIFT KeyDATAENTERfor more than one second.(DATA/ENTER Key)The value blinks and is saved.DATA(DATA/SHIFT Key)(Press at least 1 s.)5 Press the DATA/ENTER Key once, or DATA/SHIFT KeyDATAENTERfor more than one second to return to the display Pn50E.(DATA/ENTER Key)DATA(DATA/SHIFT Key)(Press at least 1 s.)6 Press the UP Key to set Pn50F.Note: The enabled digit blinks.(UP Key)(UP Key)7 Press the DATA/ENTER Key once, or DATA/SHIFT KeyDATAENTERDATA for more than one second to display the current data of(DATA/ENTER Key) (DATA/SHIFT Key) Pn50F.(Press at least 1 s.)(/BK is set to “Invalid.”)8 Press the LEFT or RIHGT Key or DATA/SHIFT Key toselect the third digit from the right. Press the UP Key to setDATA/“2.”(DATA/SHIFT Key)(Allocates /BK to CN1-27 (28).)9 Press the DATA/ENTER Key once, or DATA/SHIFT KeyDATAENTER(DATA/ENTER Key)DATA(DATA/SHIFT Key)(Press at least 1 s.)for more than one second. The value blinks and is saved.10 Press the DATA/ENTER Key once, or DATA/SHIFT KeyDATAENTERDATA for more than one second to return to the display Pn50F. /(DATA/ENTER Key) (DATA/SHIFT Key) TGON is set as “Invalid” and /BK is allocated to CN1-27(Press at least 1 s.)(28).11 Turn OFF the power and ON again to enable the changes of output signal selection (Pn50E and Pn50F).77-27

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!