10.07.2015 Views

Sigma-II Series SGM*H/SGDH USER'S MANUAL - Esco Drives ...

Sigma-II Series SGM*H/SGDH USER'S MANUAL - Esco Drives ...

Sigma-II Series SGM*H/SGDH USER'S MANUAL - Esco Drives ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

7.3 Operation in Parameter Setting Mode (Pn)(3) Allocating Input SignalsEXAMPLEPn50A:Pn50B:The procedure to replace Servo ON (/S-ON) signal allocated to CN1-40 and Forward External Torque Limit(/P-CL) allocated to CN1-45 is shown below.BeforeAfterStepDisplay after DigitalOperation OperatorPanel OperatorDescription1 Press the DSPL/SET or MODE/SET Key to select theDSPLSET“value setting parameter” mode. If a parameter other(DSPL/SET Key) MODE/SET than Pn50A is displayed, press the UP or DOWN Key to(MODE/SET Key)set Pn50A.Note: The enabled digit blinks.2 Press the DATA/ENTER Key once, or DATA/SHIFTDATAENTER(DATA/ENTER Key)DATA(DATA/SHIFT Key)(Press at least 1 s.)Key for more than one second to display the current dataof Pn50A.(/S-ON is allocated to CN1-40.)3 Press the UP Key to set to “1.”(Sequence input signals can be freely set.)DATA/(UP Key)(DATA/SHIFT Key)4 Press the LEFT or RIGHT Key or DATA/SHIFT Key toselect the second digit from the right. Press the UP keyDATA/ to set to “5.”(DATA/SHIFT Key)(Changes the allocation of /S-ON from CN1-40 to CN1-45.)5 Press the DATA/ENTER Key once, or DATA/SHIFTKey for more than one second. The value blinks and isDATAENTERDATA(DATA/SHIFT Key) saved.(DATA/ENTER Key) (Press at least 1 s.) At the moment, the CN1-45 operates with OR logic for/S-ON and /P-CL.6 Press the DATA/ENTER Key once, or DATA/SHIFTDATAENTER(DATA/ENTER Key)DATA(DATA/SHIFT Key)(Press at least 1 s.)Key for more than one second to return to the displayPn50A.7 Press the UP Key to set Pn50B.Note: The enabled digit blinks.(UP Key)(UP Key)8 Press the DATA/ENTER Key once, or DATA/SHIFTDATAKey for more than one second to display the current dataENTERDATAof Pn50B.(DATA/ENTER Key)(DATA/SHIFT Key)(Press at least 1 s.)(/P-CL is allocated to CN1-45.)9 Press the LEFT or RIGHT Key or DATA/SHIFT Key toselect the third digit from the right. Press the DOWNDATA/Key to set to “0.”(DATA/SHIFT Key)(Changes the allocation of /P-CL from CN1-45 to CN1-40.)10 Press the DATA/ENTER Key once, or DATA/SHIFTDATAENTER(DATA/ENTER Key)DATA(DATA/SHIFT Key)(Press at least 1 s.)Key for more than one second. The value blinks and issaved.11 Press the DATA/ENTER Key once, or DATA/SHIFTDATAKey for more than one second to return to the displayENTERDATA/ Pn50B. /S-ON is allocation to CN1-45, and /P-CL is(DATA/ENTER Key) (DATA/SHIFT Key)allocated to CN1-40.12 Turn the power OFF and ON again to enable the change of input signal selections (Pn50A and Pn50B).77-25

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!