7.3 Operation in Parameter Setting Mode (Pn)For details on each digit of the parameter, see 11.3.2 List of Parameters.ParameterPn50A n.2n.8MeaningInput the forward run prohibited signal (P-OT) from CN1-42 (Factory setting).Forward run prohibited signal (P-OT) is disabled (Forward rotation allowed).The number of theparameterThis blank shows the settingvalue of the function selection,as well as the state conditionon the panel operator and thedigital operator (JUSP-OP02A-2).This section explains thedetails of the function selection.7.3.2 Input Circuit Signal AllocationEach input signal is allocated to a pin of the input connector CN1 by setting the parameter.The following table shows detailed allocation.(1) Factory Setting (Pn50A.0 = 0)The factory setting for the input signal allocation is as follows.means factory setting.Pn50A:Pn50B:77-23