7 Digital Operator/Panel Operator7.2.5 Alarm Traceback Data Clear (Fn006)7.2.5 Alarm Traceback Data Clear (Fn006)This function clears the alarm traceback data, which stores the alarms generated in the SERVOPACK.After having cleared data, “A.--” (No alarm) is set to all the alarm traceback data.StepDisplay afterOperationDigital Operator Panel Operator Description1 Press the DSPL/SET or MODE/SET Key to select theDSPLSET(DSPL/SET Key)MODE/SET(MODE/SET Key)utility function mode.2 Press the UP or DOWN Key to select Fn006.Note: The enabled digit blinks.3 Press the DATA/ENTER Key once, or DATA/SHIFTDATAENTERKey for more than one second, and the display will be(DATA/ENTER Key)as shown on the left.DATA(DATA/SHIFT Key)(Press at least 1 s.)4 Press the DSPL/SET or MODE/SET Key to clear theDSPLSETalarm traceback data.(DSPL/SET Key) MODE/SETThe display shown on the left blinks for about one secondwhen the data is cleared.(MODE/SET Key)5 After about one second The display changes from “donE” to the displayshown on the left.6 Press the DATA/ENTER Key once, or DATA/SHIFTDATAENTERKey for more than one second to return to the utility(DATA/ENTER Key)function mode display Fn006.DATA(DATA/SHIFT Key)(Press at least 1 s.)7-12