5.2 Servomotor Main Circuit Wire Size and Connectors5.2.6 SGMSH Servomotor (3000 min -1 ) Connectors for Standard Environments(1) 200 V and 400 V Servomotors Without Holding BrakesThe specifications are same for both three-phase 200 V and 400 V servomotors.Capacity(kW)1.01.52.03.04.05.0Connector onServomotorStraightPlugL-shapedCable ClampMS3102A18-10P MS3106B18-10S MS3108B18-10S MS3057-10AMS3102A22-22P MS3106B22-22S MS3108B22-22S MS3057-12A(2) 200 V and 400 V Servomotors With Holding BrakesThe three-phase 400 V 1.0 to 5.0 kW servomotors require (a) servomotor-end connector and (b) brake powersupply connector.(a) Servomotor-end Connectorsi) 200 V Servomotors5Capacity(kW)1.01.52.03.04.05.0Connector onServomotorStraightPlugL-shapedCable ClampMS3102A20-15P MS3106B20-15S MS3108B20-15S MS3057-12AMS3102A24-10P MS3106B24-10S MS3108B24-10S MS3057-16Aii)400 V ServomotorsCapacity(kW)1.01.52.03.04.05.0Connector onServomotorStraightPlugL-shapedCable ClampMS3102A18-10P MS3106B18-10S MS3108B18-10S MS3057-10AMS3102A22-22P MS3106B22-22S MS3108B22-22S MS3057-12A5-17