10.07.2015 Views

Approved Materials List - City of Kamloops

Approved Materials List - City of Kamloops

Approved Materials List - City of Kamloops

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

LIST OF APPROVED PRODUCTS AND MATERIALSThe following products have been reviewed by the <strong>City</strong> <strong>of</strong> <strong>Kamloops</strong> <strong>Materials</strong> Approval Committee and have been deemed to meet <strong>City</strong> <strong>of</strong> <strong>Kamloops</strong> specifications.Products not on this list require the specific written approval <strong>of</strong> the Engineering Manager for use.Last Modified: 10-Mar-2014MMCD REFERENCEAPPROVED PRODUCTCOMMENTSSECTION SUB-SECTION MANUFACTURER - Series or Model NameRecent ammendments are shown in red25 56 01These two sections are listed together - they make up what was the Electrical Section (16650) <strong>of</strong> the Gold BookROADWAY LIGHTING 2.10.1 Conductor Connectors Buchanan B Cap (B2-1 or B4-1) These connectors fit the DB splice kits required in the J.B's2.9.1AND2.11.12.10Fuses and Fuse HoldersBuss-HEBAA 30A 600V c/w fuse boot34 41 13Gould 11-1130A 600V c/w fuse bootTRAFFIC SIGNALS 2.11 Service Panels Wesco – Model: P1B260-12-DNBA-SE Valid MFG. Model: BSD 1A242.16 Traffic and Pedestrian Signals Traffic Heads/Backboards: Econolite CanadaPedestrian Heads: Siemens (Interprovincial) -All heads to be Yellow poly unless otherwise specified.Pedestrian Heads - Yellow 425 x 476mmBackboard Tape: 3M Diamond grade 4081 Flourecent Yellow2.17 LED Signal Modules Dialight L.E.D.S - ITE Standard2.19 Signal Mounting Hardware Mid Span plumbizers: Greenlite TrafficSecondary brackets: Greenlite TrafficClamshell Brackets: Interprovincial Traffic. (Pedestrian)2.20 Audible Signals Novax 3000i P/N P/S 003001 and P/N P/S 003077 Mounted inside head. C/W voice message.2.21 Pedestrian/Cyclist Pushbuttons Pedestrian PushButton Sign/Greenlite Traffic GEL 239LY/RYPowder coat Black on YellowPedestrian Pushbutton/Polara Engineering -Bulldog BDSP-014-Y2.22 Luminaires Holophane LEDengd, Holophane Laneview/American Lighting, Cree LEDwaySeries, Cree XSP Series, Lumec RoadstarStyle and Wattage to determined by ContractAdministration2.23 High Intensity Discharge Lamps Sylvania or Phillips 150W/55V HPS or 100W/100V HPS2.243.10Photo ControlsLuminaires and PhotocellsFisher Pierce OLC-7793-EPS 250-377 volts, 7790B-SSS 105- 305 volts. Dark to Light (DTL) is a division <strong>of</strong> American Electric Light(AEL)Dark to Light (DTL) D124-1.5-5TM, 105-305 volts.2.26 NEMA Traffic Controllers Econolite Canada.2.28 Uninterruptable Power Supply Tech DBL 700 MXD-. UPS DBL 700MX/wdial timer & RM Ears & Cable set for 6 UPS to come complete with Stannd alone cabinetBatteries.(Econolite) and 6 batteries(50AH 12v)3.6 Poles and Related Equipment West Coast Eng. Group. -SD-278, SD-248, SD-308, or B.C. MOTH Traffic Type1,Type 3, Type 7, Type L, Type S.NOVA Pole International Inc. NSD-278,NSD-248, NSD-308, or B.C. MOTHTraffic Type 1,Type 3, Type 7, Type L, Type S.Lumec Inc. (luminaire-100-hps-LL20-PC-FC-RR#120-GNTX-LMS6792F and Pole.-SPR4D-15-GNTX-LMS6792F); luminaire – 11MH-DMS 10 SG3-120-DL-LR-IF-1Aand pole – SPR4D-14-PH8/120-LBC2-3/4X20-8-DEC-GN4TX-LMS10518A)Approval for all street lights are location dependant andrequire the specific approval <strong>of</strong> the Development andEngineering Services Department. This list includesLuminaire/pole combinations that have been previouslyaccepted by the <strong>City</strong> <strong>of</strong> <strong>Kamloops</strong> but does not implyautomatic approval. For decrotive LUMEC INC. Street lightsreference design drawing "LL20 55716A 15' Post top - 3 rdAve", or "DMS20-north shore revite".3.7 3.7 Signal mounting "Signal Sax" West Coast Enginerring or Trans Canada traffic. Sacs must cover head completely but allow indications to bevisable for "Flash Out" <strong>of</strong> intersection.31 32 19GEOSYNTHETICS31 36 133.12.1S Traffic Signal Kiosk Valid Maufacturing Ltd Part #KSDC401616-E, Harrioson Industrial Ltd Part #1616402.1 Geosynthetic2.1 GabionsPage 1 <strong>of</strong> 6


LIST OF APPROVED PRODUCTS AND MATERIALSLast Modified: 10-Mar-2014MMCD REFERENCEAPPROVED PRODUCTSECTION SUB-SECTION MANUFACTURER - Series or Model NameRecent ammendments are shown in redGABIONS 25 56 01 2.2 Gabion Mats or Geogrids These two sections are listed together - they make up what was the Electrical Section (16650) <strong>of</strong> the Gold Book32 01 17.62.1.1 <strong>Materials</strong> - General - Rubberized and elasticized asphaltSEALING PAVEMENTsealantCRACKS FOR2.1.2 <strong>Materials</strong> - General - High float emulsified asphaltMAINTENANCE PURPOSES32 14 01UNIT PAVING32 17 23PAINTED PAVEMENTMARKINGS33 11 01WATERWORKS2.1.5 <strong>Materials</strong> - Unit pavers2.1.6 <strong>Materials</strong> - Edge restraint2.1.3 <strong>Materials</strong> - Paint to BC MOT mix design2.1.5 Sign <strong>Materials</strong> - Glass beads to BC MOT spec2.2.1 Mainline Pipe, Joints and Fittings - Ductile iron pipe CANADA PIPE COMPANY LTD SIZES 100-500mm2.2.2 Mainline Pipe, Joints and Fittings - Polyvinyl ChlorideSIZES 100-500mm(PVC) Pressure Pipe2.2.4.1 Mainline Pipe, Joints and Fittings - Fittings - Gray-iron(cast iron)IPEX INC - Blue Brute, TerraBruteREHAU INDUSTRIES LTD - AQUALOC® Municipal PVCROYAL PIPE SYSTEMS - Royal Seal CIOD2.2.4.2 Mainline Pipe, Joints and Fittings - Fittings - Ductile iron TERMINAL CITY IRON WORKS LTDSTAR PIPE PRODUCTSUNION FOUNDRY COMPANYSIGMA CORPORATIONSIGMA - MJ Fittings C153 (2"-48"); Trim Tyton C153 Push on (4"-24"); MJFittings (DI) C110 (3"-48"); Push On Fittings (DI) C110 (4"-12"); Flanged Fittings(DI) C110 (3"-12")2.2.4.3 Mainline Pipe, Joints and Fittings - Fittings - Compactductile ironTERMINAL CITY IRON WORKS LTDSTAR PIPE PRODUCTSUNION FOUNDRY COMPANYSIGMA CORPORATION2.2.4.4 Mainline Pipe, Joints and Fittings - Fittings - PVC injection-IPEmolded INCROYAL PIPE SYSTEMSHARCO - Injected Moulded Fittings2.2.4.5 Mainline Pipe, Joints and Fittings - Fittings - PVC IPEX INCextrudedROYAL PIPE SYSTEMSGALAXY PLASTICS C900 PVC Fittings (4'"-36")2.2.4.12 Mainline Pipe, Joints and Fittings - Fittings - Couplings ROBAR INDUSTRIES LTDVIKING JOHNSON2.2.4.12 Mainline Pipe, Joints and Fittings - Fittings - FlangedCoupling AdaptorsSMITH-BLAIR INC - Omni TM Coupling SystemTOTAL PIPING SOLUTIONS INC - Hymax-2000ROMAC INDUSTRIES INC.UNI-FLANGESTAR PIPE PRODUCTSSMITH-BLAIR INCTOTAL PIPING SOLUTIONS INC - Hymax-2100ROMAC INDUSTRIES INC.COMMENTSSee supplementary clause in <strong>City</strong> Standard Amendments -Gray iron (cast iron) fittings shall not be used in the <strong>City</strong> <strong>of</strong><strong>Kamloops</strong>SIZES 100-400mmpush-on bell and spigot type joint or flanged joint(mechanical pipe joints not allowed)SIZES 100-400mmpush-on bell and spigot type joint or flanged joint(mechanical pipe joints not allowed)SIZES 100-300mmAll fittings must meet pressure testing standard CSA B137.2.SIZES 100-400mm - IPEXSIZES 100-1200mm - ROYAL PIPE,SIZES 100-900mm GALAXY PLASTICSnote: Viking Johnson couplings distributed by MuellerCanada Inc. Smith Blair couplings distributed by CanadaPipeline Acc. Corp.<strong>City</strong> will be reviewing all couplings - approved products mustmeet AWWA C219<strong>City</strong> will be reviewing all flanged coupling adaptors -approved products must meet AWWA C219Page 2 <strong>of</strong> 6


LIST OF APPROVED PRODUCTS AND MATERIALSLast Modified: 10-Mar-2014MMCD REFERENCEAPPROVED PRODUCTSECTION SUB-SECTION MANUFACTURER - Series or Model NameRecent ammendments are shown in red25 56 01 2.2.4.13 Mainline Pipe, Joints and Fittings - Fittings These two - Joint sections are UNI-FLANGE listed together - Series - they 1400 make up what was the Electrical Section (16650) <strong>of</strong> the Gold BookRestraint DevicesSTAR PIPE PRODUCTS - Series 3000CLOW CANADA - Series 1300/1350/1360EBAA IRON INCSMITH BLAIR - Pipe LockROMAC INDUSTRIES INC.33 11 012.2.4.14 Mainline Pipe, Joints and Fittings - Fittings - Tapping ROBAR INDUSTRIES LTD - Series 6606, 6906, 6926WATERWORKSsleeves for branch connections 75mm and larger MUELLER CANADA INC - H-621(CONTINUED)SMITH-BLAIR INC - 662 and 6632.2.4.15 Mainline Pipe, Joints and Fittings - Fittings - RepairclampsROMAC INDUSTRIES INC.CANADA PIPELINE ACCESSORIES CORP - CR-2, CR-3ROBAR INDUSTRIES LTD - Series 5626, and 5636VIKING JOHNSON - MaxiFit TMCLOW CANADA - ConcordTOTAL PIPING SOLUTIONS INC - EZ-Max Plus 40002.3.2 Valves and Valve Boxes - Mainline Gate valves AMERICAN AVKCLOW CANADAMUELLER CANADA INC2.3.3 Valves and Valve Boxes - Mainline butterfly valves PRATT - GroundhogMUELLER CANADA INC - Lineseal III & XPCLOW CANADA - M&H Direct Bury2.3.4 Valves and Valve Boxes - Standpipes TERMINAL CITY IRON WORKS LTD - 50mm Terminal <strong>City</strong> Self DrainingStandpipe c/w Adapter & Cap2.3.5 Valves and Valve Boxes - Air Release, Air/Vacuum andCombination Air Valves2.3.6 Valves and Valve Boxes - Mainline Valve Boxes TERMINAL CITY IRON WORKS LTD - Robar Type WESTVIEW SALES LTD - RobarTypeCOMMENTSsee supplementary clause in C<strong>of</strong>K Standard Amendmentssee supplementary clause in C<strong>of</strong>K Standard Amendments.50mm size.Only Robar Type valve boxes approved for use. MR typeand Nelson Type valve boxes removed from <strong>List</strong>, Nov 2006.2.3.7 Valves and Valve Boxes - Service Valve Boxes TROJAN - CCSB1CONCORD - CCSB1 TypeMcAVITY2.3.8 Valves and Valve Boxes - Check Valves TERMINAL CITY IRON WORKS LTDMUELLER CANADA INC2.5.1 Service Connections, Pipe, Joints and Fittings - Pipediameter 19mm to 50mm2.5.3.2 Service Connections, Pipe, Joints and Fittings - Servicesaddles - DINORANDA - Type K CopperWOLVERINE - Type K CopperIPEX INC - Q-Line®, Blue 904 (Pex)REHAU - Municipex® (PEXa)ROBAR INDUSTRIES LTD - 2616 DB, 2626 DB, 2706 DSSMITH-BLAIR INC - 372, 393CAMBRIDGE BRASS - Model 812IPEX - Blue Brute Fittings Single Tapped Coupling2.5.3.3 Service Connections, Pipe, Joints and Fittings - Servicesaddles - PVC2.6 Hydrants CLOW CANADA - BRIGADIER M93Sizes 100-400mmOnly 19mm, 25mm & 50mm servces permittedCopper to be Warnock Hersey CertifiedBlue904 and Municipex® services must include tracer wireon all services not perpendicular to the mainline and on allservices longer than 20m.Kitec removed from listIPEX - couplings for 150mm and 200mm diameter mainlineonlyPage 3 <strong>of</strong> 6


LIST OF APPROVED PRODUCTS AND MATERIALSLast Modified: 10-Mar-2014MMCD REFERENCEAPPROVED PRODUCTCOMMENTSSECTION SUB-SECTION MANUFACTURER - Series or Model NameRecent ammendments are shown in red25 56 01 2.7.2 Underground Service Line Valves and These Fittings two - sections are FORD listed together - they make up what was the Electrical Section (16650) <strong>of</strong> the Gold Non-draining, Book full flow, full port ball type.Corporation StopsMUELLER CANADA INCAY MCDONALD MFG COCAMBRIDGE BRASS33 11 01WATERWORKS(CONTINUED)2.7.3 Underground Service Line Valves and Fittings - CurbStopsFORDMUELLER CANADA INCAY MCDONALD MFG CONon-draining, full flow, full port ball type.33 30 01SANITARY SEWERS33 34 01SEWAGE FORCEMAINS33 40 01STORM SEWERSCAMBRIDGE BRASS2.1.1 Concrete Pipe - Non-reinforced concrete pipe and fittings see supplementary clause in C<strong>of</strong>K Standard Amendments -Non-reinforced concrete pipe shall not be used in the <strong>City</strong> <strong>of</strong><strong>Kamloops</strong>2.1.2 Concrete Pipe - Reinforced circular concrete pipe and LANGLEY CONCRETE & TILE LTDfittingsOCEAN CONSTRUCTION SUPPLIES LTD2.2 Plastic Pipe, Mainline Smooth Pr<strong>of</strong>ile - Polyvinyl chloride IPEX INC - Ring-Tite TMpipe up to 675mm in diameterREHAU INDUSTRIES LTD - Duraloc® PVC Sewer PipeROYAL PIPE SYSTEMS2.3 Service Connections ROYAL PIPE SYSTEMS - Inspection Chambers and CSA certified PVC sewerfittingsGALAXY PLASTICS LTD - Inspection Chambers and CSA certified PVC sewerfittingsPRO-LINE FITTINGS INC - Inspection Chamber (4" Adapt-a-Valve TM IC) and CSAcertified PVC sewer fittings.MAINLINE BACKFLOW PRODUCTS INC - Inspection Chamber (Mainline 4"Adapt-a-Valve TM Inspection Chamber, IC SEWER ACCESS lid, and collars).2.3.8.2 Service Connections - Insertable Tee Products Insertable tee products (like Inserta-Tees®, Uni-T, E-Z-Tee etc.) may beapproved for use under retr<strong>of</strong>it, rehabilitation, or emergency repairconstruction only. Contact <strong>City</strong> Engineer/Project Manager for approval. Theseproducts are NOT APPROVED for new construction. Design Engineer mustinstead specify appropriate sewer fittings.2.2 Pipe, Joints and fittings2.3 Valves and Valve Boxes2.4 Valve Chambers2.1.1 Concrete Pipe - Non-reinforced circular concrete pipe andfittings2.1.2 Concrete Pipe - Reinforced circular concrete pipe andfittings2.2.1 Plastic Pipe, Mainline Smooth Pr<strong>of</strong>ile and PerforatedDrain Tile - Polyvinyl chloride pipe up to 1200mm indiameterLANGLEY CONCRETE & TILE LTDOCEAN CONSTRUCTION SUPPLIES LTDIPEX INC - Ring-Tite TMREHAU INDUSTRIES LTD - Duraloc® PVC Sewer PipeROYAL PIPE SYSTEMS2.3.1 Plastic Pipe, Mainline Ribbed Pr<strong>of</strong>ile - PVC Ribbed Pipe IPEX INC - Ultra-Rib TM , Perma-Loc TM Class V, Ultra-X2REHAU INDUSTRIES LTD - RAURIBROYAL PIPE SYSTEMS - Royal Kor Flo TM2.3 Plastic Pipe, Smooth Pr<strong>of</strong>ileConfirmed PRO-LINE FITTINGS INC - Inspection Chamber is(4" Adapt-a-Valve TM Inspection Chamber) and ismanufactured by MAINLINE BACKFLOW PRODUCTS INC. -corrected and Manufacturer added to list - August 2011see supplementary clause in C<strong>of</strong>K Standard Amendments -Non-reinforced concrete pipe shall not be used in the <strong>City</strong> <strong>of</strong><strong>Kamloops</strong>LOC PIPE removed from list, Oct 2006.Page 4 <strong>of</strong> 6


LIST OF APPROVED PRODUCTS AND MATERIALSLast Modified: 10-Mar-2014MMCD REFERENCEAPPROVED PRODUCTCOMMENTSSECTION SUB-SECTION MANUFACTURER - Series or Model NameRecent ammendments are shown in red25 33 56 40 012.4 HDPE Pipe, Mainline Open Pr<strong>of</strong>ile These two sections are POLYTUBES listed together (PACIFIC) - they INC make - Big up 'O' what Boss was 2000 the Electrical Section (16650) <strong>of</strong> the Gold A wide Book range <strong>of</strong> BOSS 2000 products are manufactured.STORM SEWERSEach is designed differently to meet the needs <strong>of</strong> specific(CONTINUED)ARMTEC - Boss 2000ADS/HANCOR - Blue Seal®standards. ONLY CSA Certified Boss 2000 sizes 100-600mmfrom POLYTUBES (Pacific) INC (Langley Plant) and sizes 375-900mm supplied by ARMTEC Prince George, BC have beenapproved by the <strong>City</strong> <strong>of</strong> <strong>Kamloops</strong>.Blue Seal® approved for 100-750mmBlue Seal® (triple wall pipe) may be approved for 900mm -contact <strong>City</strong> Engineer or PM for approvalHDPE pipe for storm applications must have CSA B182.8certification and all storm sewers must pass air test. Refer to<strong>City</strong> Ammendments to the Specifications.2.5 Spiral Rib Pipe-Steel2.6 Service Connections ROYAL PIPE SYSTEMS - Inspection Chamber and CSA certified PVC sewerfittingsGALAXY PLASTICS LTD - Inspection Chamber and CSA certified PVC sewerfittingsPRO-LINE FITTINGS INC - CSA certified PVC sewer fittingsRemoved Inspection Chamber from PRO-LINE FITTINGS INC -(4" Adapt-a-Valve TM IC) is only available in 100mm and notthe <strong>City</strong> required 150mm min. for Storm - August 20112.6.8.2 Service Connections - Insertable Tee Products Insertable tee products (like Inserta-Tees®, Uni-T, E-Z-Tee etc.) may beapproved for use under retr<strong>of</strong>it, rehabilitation, or emergency repairconstruction only. Contact <strong>City</strong> Engineer/Project Manager for approval. Theseproducts are NOT APPROVED for new construction. Design Engineer mustinstead specify appropriate sewer fittings.2.11 High Density Polyethylene Pipe (smooth wall) KWH PIPE (CANADA) LTD - Weholite, and Sclairpipe see supplementary clause in C<strong>of</strong>K Standard Amendments -Use only for trunk-mains with no potential for any servicesto be connected. Minimum 5% grade. Designer mustconsider expansion and contraction.33 42 13PIPE CULVERTS33 44 01MANHOLES ANDCATCHBASINSMaximum 300mm to 600mm Diameter2.1 Corrugated Steel Pipe ARMTEC LTDATLANTIC INDUSTRIES LTD2.2 Concrete Pipe not approved for culverts2.3 Plastic Pipe, Smooth Pr<strong>of</strong>ile not approved for culverts2.4 PVC Pipe Pr<strong>of</strong>ile not approved for culverts2.5 HDPE Plastic Pipe, Open Pr<strong>of</strong>ile ADS/HANCOR - Blue Seal®, Hi-Q®POLYTUBES (PACIFIC) INC - Big 'O' Boss 2000ARMTEC - Boss 20002.1.7 Material - Cast iron (manhole) frame and cover TERMINAL CITY IRON WORKS LTD - C-18WESTVIEW SALES LTD - TR-18TERMINAL CITY IRON WORKS LTD - C-44A (Adjustable Manhole Frame andSupport Ring)STAR PIPE PRODUCTS - MHCW18 (C-18 MH Frame and Cover)2.1.13 Material - Cast iron catchbasin frame and grate DOBNEY FOUNDRY - B-18 see SS11a Catchbasin Type I2.1.13 Material - Cast iron catchbasin frame and grate (roll overcurb)TROJAN INDUSTRIES - Type K-2 / Type K-5DOBNEY FOUNDRY - T-K7see SS11c Catch Basin Type IIIRemoved DOBNEY FOUNDRY B-36BPage 5 <strong>of</strong> 6


LIST OF APPROVED PRODUCTS AND MATERIALSLast Modified: 10-Mar-2014MMCD REFERENCEAPPROVED PRODUCTCOMMENTSSECTION SUB-SECTION MANUFACTURER - Series or Model NameRecent ammendments are shown in red25 56 01 2.1.16 Material - Adjusting rings These two sections are IPEX listed LifeSaver together - Manhole - they make and up Catchbasin what was Adjustment the Electrical System Section (16650) <strong>of</strong> the Gold Book2.1.19 Material - Lawn Drains DOBNEY FOUNDRY - D22, D2A see SS12 Lawn Drains2.0 - Misc. Material - Composite reinforced polymer concreteheadwallsARMTEC LTD - Pro-eco-lite TM HeadwallsUse only for 375mm pipe and smaller. Railing and grillagerequirements as per standard detail drawings SS13 & SS1434 41 15STRAFFIC CONTROL DEVICES03310SSEGMENTAL CONCRETEWALL UNITS2.1.2 Sign <strong>Materials</strong> - Pole UNISTRUT - Telespar Poles2.1.4 Sign <strong>Materials</strong> - Sign sheeting 3M SCOTCHLITE2.1.1 <strong>Materials</strong> - Segmental concrete wall unitsRetaining wall face must aesthetically and sensitively integrate into the surrounding neighbourhood, based on the sole discretion <strong>of</strong> the <strong>City</strong><strong>of</strong> <strong>Kamloops</strong>.A registered pr<strong>of</strong>essional (Engineer) shall undertake the design and conduct field reviews <strong>of</strong> the construction <strong>of</strong> a retaining structuregreater than 1.2 m (4 ft.) in height,' Building By-law No. 11-80.Questions or Comments? Contact:Rachel Driedger, Assistant Design Engineer<strong>City</strong> <strong>of</strong> <strong>Kamloops</strong> Engineering Division105 Seymour St, <strong>Kamloops</strong>, BC, V2C 2C6P: 250-828-3727F: 250-828-7848e: rdriedger@kamloops.caPage 6 <strong>of</strong> 6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!