10.07.2015 Views

UPS 1200 SERIES, SINGLE MODULE SYSTEM - Peterson Power

UPS 1200 SERIES, SINGLE MODULE SYSTEM - Peterson Power

UPS 1200 SERIES, SINGLE MODULE SYSTEM - Peterson Power

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

UNINTERRUPTIBLEPOWER SUPPLY (<strong>UPS</strong>)<strong>UPS</strong> <strong>1200</strong> <strong>SERIES</strong>,<strong>SINGLE</strong> <strong>MODULE</strong><strong>SYSTEM</strong><strong>1200</strong> kVA/960 kW, 60 Hz3 wireCaterpillar is leading the power generationmarketplace with <strong>Power</strong> Quality Solutionsengineered to deliver unmatched flexibility,expandability, reliability and cost-effectiveness.FEATURES● Smallest available footprint● 97% total system efficiency● Harmonic cancellation● Transient protection● High-speed voltage regulation● <strong>Power</strong> factor correction● Top and bottom cable entry● 40° C rating on entire system● Low input current distortion● Utilize kinetic power cell technology● Remote monitoring● Simple installation● Low maintenance● Field expandable ride-through● Color user interface display● Optional generator set start moduleRELIABLE POWER PROTECTIONFOR CRITICAL APPLICATIONSCat ® <strong>UPS</strong> systems provide constant powerprotection against surges, sags and powerinterruptions that can disrupt operations orcause loss of valuable data or system capacity.Additionally, the use of the optional generator setstart module can dramatically increase generatorset starting reliability in a continuous powerconfiguration.SUPERIOR DESIGNSuperior system design and the use of robustdigital components throughout the system yieldthe most reliable and trouble-free <strong>UPS</strong> systemon the market. Protection is delivered in theindustry’s smallest package with the highestefficiency and superior performance.GENERATOR SET INTEGRATIONBy cancelling harmonic distortion, the <strong>1200</strong> Seriesoperates seamlessly with generator sets to providea higher total electrical load capacity withoutover-sizing the generator set. The <strong>1200</strong> Serieseffectively insulates the generator set from blockloads and transients, and can improve its faultclearing capabilities. Programmable integrationwith standby generator sets assures greater systemreliability and improves the total system operation.WORLDWIDE PRODUCT SUPPORT● Parts Distribution Centers are located worldwidewith available service support through Caterpillarand the Cat Dealer Network.● Factory certified service technicians are trainedto support every aspect of your Cat <strong>UPS</strong> system.LEHE3445-02


<strong>UPS</strong> <strong>1200</strong> <strong>SERIES</strong>,<strong>SINGLE</strong> <strong>MODULE</strong> <strong>SYSTEM</strong>FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENTSTANDARD FEATURESFull rated continuous duty static bypass switchRedundant control power suppliesLocal Emergency <strong>Power</strong> Off (EPO)<strong>UPS</strong> View — monitoring/communication softwareRS232 and RS485 serial connectionFeature rich 10.4" color touch screen, graphical user interfaceInternal modemProgrammable monitoring and alarm input and output contactsMODBUS CommunicationRedundant cooling fansAuto restart (programmable)Back feed protectionEthernet communication portDual-flywheel energy storage cabinetsMounting hardware – seismic ratedVoltage regulation and power factor correctionHarmonic cancellationOPTIONAL FEATURES24 volt DC, generator set starting powerAdditional flywheel available for increased ride throughRemote EPORemote status panelSNMP CommunicationMaintenance bypassOutput Isolation BreakerSPECIFICATIONSINPUTVoltageVoltage RangeFrequency<strong>Power</strong> Factor480 VAC 3 phase, 3-wire plusground (from groundedwye source)+10%/–15% (programmable)60 Hz0.99 at rated load andnominal voltageHarmonic Current DistortionLinear load


<strong>UPS</strong> <strong>1200</strong> <strong>SERIES</strong>,<strong>SINGLE</strong> <strong>MODULE</strong> <strong>SYSTEM</strong>DIMENSIONS & WEIGHTSAll CabinetsDepth 1016 mm 40.0 inCabinet height 1981 mm 78.0 in(w/out DC bus)System height (w/DC bus) 2319 mm 91.3 inMaintenance By-pass (option)Width 533 mm 21.0 inWeight 907 kg 2000 lbBottom Entry (option)Width 1067 mm 42.0 inWeight 817 kg 1800 lbInput/OutputWidth 1067 mm 42.0 inWeight 1134 kg 2500 lbStatic SwitchWidth 1067 mm 42.0 inWeight 923 kg 2035 lbControl (Note: ships attached to Inverter Cabinet)Width 914 mm 36.0 inWeight 907 kg 2000 lbInverter (Note: ships attached to Control Cabinet)Width 1067 mm 42.0 inWeight 771 kg 1700 lbEnergy Storage/each — 2 per standard systemWidth 1067 mm 42.0 inWeight 3040 kg 6700 lbTECHNICAL DATAMaximum kVA <strong>1200</strong>Maximum kW 960Input voltage 480Output voltage 480AC input currentNominal amps 1205Maximum amps incl. recharge 1600AC output current nominal amps 1445System efficiency (3-wire) 97%Heat rejection*<strong>UPS</strong> <strong>1200</strong> Series 3WNominal BTU/hr (kW) 92,150 (27)Worst Case BTU/hr (kW) 109,898 (32.2)ENVIRONMENTALAcoustical noise


<strong>UPS</strong> <strong>1200</strong> <strong>SERIES</strong>,<strong>SINGLE</strong> <strong>MODULE</strong> <strong>SYSTEM</strong><strong>UPS</strong><strong>1200</strong>S <strong>SYSTEM</strong> FRONT ELEVATION (3 WIRE)Bypass Input / Output Static Switches Controls Inverter Energy Storage<strong>UPS</strong><strong>1200</strong>S <strong>SYSTEM</strong> ONE LINE DIAGRAM (3 WIRE)Information contained in this publication may be considered confidential.Discretion is recommended when distributing.www.cat-electricpower.comU.S. SourcedMaterials and specifications are subject to change without notice.CAT, CATERPILLAR, their respective logos, “Caterpillar Yellow” and the POWER EDGE© 2008 CaterpillarLEHE3445-02 (01-08) trade dress, as well as corporate and product identity used herein, are trademarks All Rights Reserved.of Caterpillar and may not be used without permission.Printed in U.S.A.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!