Section 2 <strong>Scanner</strong> ® <strong>2000</strong> microEFM<br />

56<br />

Table 2.2—Industry Standards for Orifice Meters<br />

Standard Applicable Section Description Notes<br />

AGA Report No. 3:<br />

Orifice Metering of<br />

Natural Gas and Other<br />

Related Hydrocarbon<br />

Fluids<br />

ISO 5167:<br />

Measurement of Fluid<br />

<strong>Flow</strong> by Means of<br />

Pressure Differential<br />

Devices Inserted in<br />

Circular Cross-Section<br />

Conduits Running Full<br />

ISO 5167:<br />

Measurement of Fluid<br />

<strong>Flow</strong> by Means of<br />

Pressure Differential<br />

Devices Inserted in<br />

Circular Cross-Section<br />

Conduits Running Full<br />

API Manual<br />

of Petroleum<br />

Measurement<br />

Standards, Chapter<br />

21.1 (Electronic Gas<br />

Measurement)<br />

Part 2: Specification<br />

and Installation<br />

Requirements,<br />

Section 2.6<br />

(Installation<br />

requirements)<br />

Part 1: General<br />

Principles and<br />

Requirements<br />

Part 2: Orifice<br />

Plates<br />

Section 1.7 -<br />

Equipment<br />

Installation<br />

Section 1.8 -<br />

Equipment<br />

Calibration and<br />

Verification<br />

Specifications for orifice<br />

meters (to include beta ratios)<br />

Installation requirements for<br />

orifice plates, meter tubes, flow<br />

conditioners, and thermometer<br />

wells<br />

Installation of orifice plates<br />

inserted into a circular crosssection<br />

conduit running full<br />

Limitation of pipe size and<br />

Reynolds number<br />

Specifies orifice plates that can<br />

be used with flange pressure<br />

tappings, corner pressure<br />

tappings, D and D/2 pressure<br />

tappings.<br />

Installation of electronic gas<br />

measurement devices and<br />

associated communications,<br />

gauge/impulse lines, and<br />

cabling<br />

Requirements for calibrating<br />

and verifying the accuracy of<br />

electronic gas measurement<br />

devices<br />

Industry Standards for Cone Meters<br />

This standard is also<br />

distributed under the<br />

following names: API<br />

MPMS Chapter 14.3, Part<br />

2; ANSI/API 14.3, Part 2-<br />

<strong>2000</strong>; and GPA 8185, Part<br />

2.<br />

ISO 5167 is applicable<br />

only to flow that remains<br />

subsonic throughout the<br />

measuring section and<br />

where the fluid can be<br />

considered single-phase.<br />

It is not applicable to the<br />

measurement of pulsating<br />

flow. It does not cover the<br />

use of orifice plates in pipe<br />

sizes less than 50 mm<br />

(2 in.) or more than 1000<br />

mm (39 in.), or for pipe<br />

Reynolds numbers below<br />

5000.<br />

For installation requirements for use with a cone meter and applicable flow rate calculations, see the NuFlo<br />

Cone Meter User Manual, Part No. 9A-85165000.