<strong>Scanner</strong> ® <strong>2000</strong> microEFM Section 2<br />

Measuring Compensated Liquid via a Turbine Meter<br />

Best Practices<br />

The <strong>Scanner</strong> <strong>2000</strong> microEFM calculates compensated liquid flow through a turbine meter in accordance with<br />

API-2540 and the measurement principles upon which the AGA-7 standard is based. The user supplies a<br />

linear or multi-point calibration factor, and the instrument performs the required compensation calculations,<br />

based on the RTD input.<br />

For optimum performance, ensure that the turbine and <strong>Scanner</strong> <strong>2000</strong> installation complies with the industry<br />

recommendations listed below:<br />

• Install the turbine flowmeter in the meter run such that there are at least 10 nominal pipe diameters upstream<br />

and five nominal pipe diameters downstream of the meter. Both inlet and outlet pipe should be of<br />

the same nominal size as the meter.<br />

• Straightening vanes are recommended for eliminating swirl conditions. If used, they should be installed<br />

five pipe diameters upstream of the meter.<br />

Installation Procedure—Direct Mount to a Turbine Meter (CSA Compliant)<br />

A <strong>Scanner</strong> <strong>2000</strong> without the MVT bottomworks can be mounted directly to a liquid turbine meter for<br />

measuring liquid (Figure 2.12). A pipe adapter and union are attached to the <strong>Scanner</strong>, allowing a direct<br />

connection to the turbine meter. An explosion-proof RTD is required for the temperature input.<br />

Adapter/union<br />

(CSA-approved)<br />

10 pipe diameters<br />

upstream<br />

<strong>Flow</strong><br />

5 pipe diameters<br />

downstream<br />

Figure 2.12—Direct-mount installation for use with a Barton 7000 Series meter<br />

Model 21<br />

explosion-proof RTD<br />

assembly or equivalent<br />

To connect the <strong>Scanner</strong> <strong>2000</strong> to a liquid turbine meter using this method, perform the following steps:<br />

1. Position the <strong>Scanner</strong> <strong>2000</strong> above the flowmeter.<br />

2. Plug the <strong>Scanner</strong> <strong>2000</strong> cable connector into the magnetic pickup of the turbine meter and hand-tighten the<br />

knurled nut on the connector.<br />

3. Screw the <strong>Scanner</strong> <strong>2000</strong> onto the flowmeter threads surrounding the magnetic pickup with the display facing<br />

the desired direction.<br />

4. Tighten all sections of the pipe union.<br />