Section 1 <strong>Scanner</strong> ® <strong>2000</strong> microEFM<br />

16<br />

Table 1.1—<strong>Scanner</strong> <strong>2000</strong> microEFM Specifications<br />

<strong>Flow</strong> Rate Calculations <strong>Steam</strong> (Orifice/NuFlo Cone):<br />

AGA Report No. 3: Orifice Metering of Natural Gas and Other Related<br />

Hydrocarbon Fluids;<br />

ISO 5167: Measurement of Fluid <strong>Flow</strong> by Means of Pressure Differential<br />

Devices Inserted in Circular Cross-Section Conduits Running Full<br />

NuFlo Cone Meter User Manual, www.c-a-m.com (Measurement Systems<br />

Division page)<br />

Liquids (Turbine):<br />

API Manual of Petroleum Measurement Standards, Chapter 5, Section 3,<br />

Measurement of Liquid Hydrocarbons by Turbine Meters<br />

Compensated Liquids (Orifice/NuFlo Cone/Turbine):<br />

AGA Report No. 3: Orifice Metering of Natural Gas and Other Related<br />

Hydrocarbon Fluids;<br />

ISO 5167: Measurement of Fluid <strong>Flow</strong> by Means of Pressure Differential<br />

Devices Inserted in Circular Cross-Section Conduits Running Full<br />

NuFlo Cone Meter User Manual, www.c-a-m.com (Measurement Systems<br />

Division page)<br />

AGA Report No. 7: Measurement of Natural Gas by Turbine Meters (as<br />

basis for liquid measurement)<br />

Fluid Property<br />

Calculations<br />

Natural Gas:<br />

AGA Report No. 8; “Compressibility Factors of Natural Gas and Other<br />

Related Hydrocarbon Gases”; Second Edition, AGA Catalogue XQ9212;<br />

American Gas Association, Arlington Virginia 1994.<br />

AGA Report No. 3, “Orifice Metering of Natural Gas and Other<br />

Hydrocarbon Fluids,” Part 3, “Natural Gas Applications,” Third Edition,<br />

1992, Appendix F, Heating Value Calculation.”<br />

GPA 2145-09, “Table of Physical Properties for Hydrocarbons and Other<br />

Compounds of Interest to the Natural Gas Industry,” Gas Processors<br />

Association, Tulsa Oklahoma, 2008.<br />

<strong>Steam</strong>:<br />

IAPWS Industrial-Formulation 1997 (IF-97)<br />

Wet Correction Methods: James and Chisholm (Orifice); Steven (NuFlo Cone)<br />

Liquids:<br />

Generic (based on user-defined constants for density and viscosity)<br />

API-2540 - 1980, Petroleum Measurement Tables<br />

MVT Provides linearized static pressure and differential pressure<br />

Available with bottom ports or side ports<br />

NACE-compliant units also available (See Table 2.1—MVT Pressure Limits,<br />

Approvals and Bolt Specifications, page 26 for bolt specifications.)<br />

Process temperature: -40°C to 121°C (-40°F to 250°F)<br />