<strong>Scanner</strong> ® <strong>2000</strong> microEFM Appendix C<br />
Register<br />
(Decimal)<br />
Holding Registers (32-bit)<br />
Register<br />
(Hex) Description<br />
Data<br />
Type Access<br />
7328 1CA0 Slave Data Point 06 FP RO<br />
7329 1CA1 Slave Data Point 07 FP RO<br />
7330 1CA2 Slave Data Point 08 FP RO<br />
7331 1CA3 Slave Data Point 09 FP RO<br />
7332 1CA4 Slave Data Point 10 FP RO<br />
7333 1CA5 Slave Data Point 11 FP RO<br />
7334 1CA6 Slave Data Point 12 FP RO<br />
7335 1CA7 Slave Data Point 13 FP RO<br />
7336 1CA8 Slave Data Point 14 FP RO<br />
7337 1CA9 Slave Data Point 15 FP RO<br />
7338 1CAA Slave Data Point 16 FP RO<br />
User-Defined Modbus Registers Configuration<br />
The <strong>Scanner</strong> <strong>2000</strong> provides a block of 25 floating point values that the user can assign to any register in the<br />
holding register map. This optimizes communication by allowing the parameters that are of interest for a<br />
given application to be organized and read in a single block read. For details on configuring User-Defined<br />
Holding Registers, see Section 3 of the ModWorX Pro Software User Manual. Each of the user-defined<br />
holding registers is determined by a pointer value in the holding register map. It is easiest to configure<br />
the pointer values with the ModWorX Pro software; however the pointer value can be determined with the<br />
following calculation: (Holding Register Number – 8000) / 2.<br />
Register<br />
(Decimal)<br />
9000 2328<br />
User-Defined Register Pointers<br />
Register<br />
(Hex) Description<br />
User-Defined Starting Address<br />
(Always 9100)<br />
Data<br />
Type Access<br />
U16 RO<br />
9001 2329 Register Pointer 1 U16 R/W<br />
9002 232A Register Pointer 2 U16 R/W<br />
9003 232B Register Pointer 3 U16 R/W<br />
9004 232C Register Pointer 4 U16 R/W<br />
9005 232D Register Pointer 5 U16 R/W<br />
9006 232E Register Pointer 6 U16 R/W<br />
9007 232F Register Pointer 7 U16 R/W<br />
9008 2330 Register Pointer 8 U16 R/W<br />
9009 2331 Register Pointer 9 U16 R/W<br />
9010 2332 Register Pointer 10 U16 R/W<br />
9011 2333 Register Pointer 11 U16 R/W<br />
9012 2334 Register Pointer 12 U16 R/W<br />
9013 2335 Register Pointer 13 U16 R/W<br />
C-43