Appendix C <strong>Scanner</strong> ® <strong>2000</strong> microEFM<br />

Fluid Property Register<br />

C-22<br />

<strong>Flow</strong> Rate Calculation<br />

6 ISA Nozzle (FUTURE)<br />

7 Long Radius Nozzle (FUTURE)<br />

8 Averaging Pitot Tube (Annubar®)<br />

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0<br />

HV SG V Isen LiqDC GPA HVRef Fluid Property Calc<br />

HV - Heating Value Selection<br />

0 Calculated<br />

1 Manual Entry<br />

SG - Specific Gravity Selection<br />

0 Calculated<br />

1 Manual Entry<br />

V - Viscosity Selection<br />

0 Calculated<br />

1 Manual Entry<br />

Isen - Isentropic Exponent Selection<br />

0 Calculated<br />

1 Manual Entry<br />

LiqDC – Liquid Density Control<br />

0 For Liquids: Register 3057 contains the flowing density<br />

For NGas: Register 3057 contains the base liquid oil density<br />

1 For Liquids: Register 3057 contains the coefficient of thermal<br />

expansion<br />

For NGas: Register 3057 contains the flowing liquid oil<br />

density<br />

GPA - GPA Table Selection<br />

0 Use 2008 Table<br />

1 Use 1996 Table<br />

HVRef - Heating Value Reference<br />

0 US (AGA) – 14.73 psi, 60 Deg F<br />

1 Canada, UK – 103.208 kPa, 15 Deg C<br />

2 Brazil (FUTURE)<br />

3 France (FUTURE)<br />

Fluid Property Calculation<br />

0 AGA-8 Detail<br />

1 AGA-8 Gross<br />

2 (FUTURE)<br />

3 IF-97 (STEAM ONLY)<br />

4 IF-97/James - (STEAM ONLY)<br />

5-15 (FUTURE)<br />

16 Generic Liquid (API 2145 Table 6C)