Appendix C <strong>Scanner</strong> ® <strong>2000</strong> microEFM<br />

Register<br />

(Decimal)<br />

C-18<br />

Register<br />

(Hex) Description<br />

Analog Input 2 Calibration<br />

Data<br />

Type Access Default<br />

2639 A4F A2 - Calibration Actual 3 FP R/W 0.00<br />

2641 A51 A2 - Calibration Actual 4 FP R/W 0.00<br />

2643 A53 A2 - Calibration Actual 5 FP R/W 0.00<br />

2645 A55 A2 - Calibration Actual 6 FP R/W 0.00<br />

2647 A57 A2 - Calibration Actual 7 FP R/W 0.00<br />

2649 A59 A2 - Calibration Actual 8 FP R/W 0.00<br />

2651 A5B A2 - Calibration Actual 9 FP R/W 0.00<br />

2653 A5D A2 - Calibration Actual 10 FP R/W 0.00<br />

2655 A5F A2 - Calibration Actual 11 FP R/W 0.00<br />

2657 A61 A2 - Calibration Actual 12 FP R/W 0.00<br />

2659 A63 A2 - Calibration Measured 1 FP R/W 0.00<br />

2661 A65 A2 - Calibration Measured 2 FP R/W 0.00<br />

2663 A67 A2 - Calibration Measured 3 FP R/W 0.00<br />

2665 A69 A2 - Calibration Measured 4 FP R/W 0.00<br />

2667 A6B A2 - Calibration Measured 5 FP R/W 0.00<br />

2669 A6D A2 - Calibration Measured 6 FP R/W 0.00<br />

2671 A6F A2 - Calibration Measured 7 FP R/W 0.00<br />

2673 A71 A2 - Calibration Measured 8 FP R/W 0.00<br />

2675 A73 A2 - Calibration Measured 9 FP R/W 0.00<br />

2677 A75 A2 - Calibration Measured 10 FP R/W 0.00<br />

2679 A77 A2 - Calibration Measured 11 FP R/W 0.00<br />

2681 A79 A2 - Calibration Measured 12 FP R/W 0.00<br />

1 The Calibration Type register must be configured using ModWorX Pro. This register defines the type and<br />

number of calibration points used. If altered manually, calibration points must be entered in ascending order.<br />

Register<br />

(Decimal)<br />

Digital Input Configuration<br />

Register<br />

(Hex) Description<br />

Data<br />

Type Access Default<br />

2900 B54 Digital Mode U16 R/W 0<br />

Register<br />

(Decimal)<br />

Register<br />

(Hex) Description<br />

3000 BB8 FR1 Volume Units<br />

See Units Table<br />

<strong>Flow</strong> Run 1 Configuration<br />

Data<br />

Type Access Default<br />

U16 R/W 201<br />

3001 BB9 FR1 Time Base U16 R/W 3<br />

3002 BBA FR1 <strong>Flow</strong> Calculation Period<br />

(Number of seconds for each<br />

calculation)<br />

U16 R/W 60<br />

3003 BBB FR1 Dampening Factor U16 R/W 0