Scanner 2000 Steam Mass Flow Transmitter ... - Spirax Sarco
Scanner 2000 Steam Mass Flow Transmitter ... - Spirax Sarco
Scanner 2000 Steam Mass Flow Transmitter ... - Spirax Sarco
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Section 1 <strong>Scanner</strong> ® <strong>2000</strong> microEFM<br />
Figure 1.3—<strong>Scanner</strong> <strong>2000</strong> microEFM for direct connection to a Barton 7000 Series turbine meter (ATEXapproved)<br />
Product Identification<br />
Each device is labeled with a serial tag that identifies the product by model number and serial number and<br />
identifies the maximum operating pressure, working pressure, and differential pressure of the integral MVT<br />
(Figure 1.4). A description of the electrical protection afforded by SIRA certification and associated safety<br />
markings is also provided in Figure 1.4.<br />
Units approved for custody transfer by Measurement Canada will have an additional label attached, bearing<br />
the MC approval number. See Measurement Canada Seal Kit, page A-14 for details.<br />
Figure 1.4—Device serial tag<br />
12<br />
CE marking and number of notified<br />
body responsible for production<br />
Explosion-proof marking<br />
Equipment Group II, Category 2 (hazardous conditions<br />
are likely to occur in normal operation occasionally (>10