<strong>Scanner</strong> ® <strong>2000</strong> microEFM Appendix C<br />

Register<br />

(Decimal)<br />

Differential Pressure Configuration<br />

Register<br />

(Hex) Description<br />

Data<br />

Type Access Default<br />

2418 972 DP - Units Scale Factor FP R/W 1.00<br />

2420 974 DP - Units Offset Factor FP R/W 0.00<br />

2422 976 DP - Unit Description 1 LCD R/W —<br />

2423 977 DP - Unit Description 2 LCD R/W —<br />

2424 978 DP - Unit Description 3 LCD R/W —<br />

Register<br />

(Decimal)<br />

Differential Pressure Calibration<br />

Register<br />

(Hex) Description<br />

Data<br />

Type Access Default<br />

2430 97E DP - Calibration Type 1<br />

U16 R/W 0<br />

2431 97F DP - Nominal Value FP R/W 1.00<br />

2433 981 DP - Calibration Absolute Offset FP R/W 0.00<br />

2435 983 DP - Calibration Actual 1 FP R/W 0.00<br />

2437 985 DP - Calibration Actual 2 FP R/W 0.00<br />

2439 987 DP - Calibration Actual 3 FP R/W 0.00<br />

2441 989 DP - Calibration Actual 4 FP R/W 0.00<br />

2443 98B DP - Calibration Actual 5 FP R/W 0.00<br />

2445 98D DP - Calibration Actual 6 FP R/W 0.00<br />

2447 98F DP - Calibration Actual 7 FP R/W 0.00<br />

2449 991 DP - Calibration Actual 8 FP R/W 0.00<br />

2451 993 DP - Calibration Actual 9 FP R/W 0.00<br />

2453 995 DP - Calibration Actual 10 FP R/W 0.00<br />

2455 997 DP - Calibration Actual 11 FP R/W 0.00<br />

2457 999 DP - Calibration Actual 12 FP R/W 0.00<br />

2459 99B DP - Calibration Measured 1 FP R/W 0.00<br />

2461 99D DP - Calibration Measured 2 FP R/W 0.00<br />

2463 99F DP - Calibration Measured 3 FP R/W 0.00<br />

2465 9A1 DP - Calibration Measured 4 FP R/W 0.00<br />

2467 9A3 DP - Calibration Measured 5 FP R/W 0.00<br />

2469 9A5 DP - Calibration Measured 6 FP R/W 0.00<br />

2471 9A7 DP - Calibration Measured 7 FP R/W 0.00<br />

2473 9A9 DP - Calibration Measured 8 FP R/W 0.00<br />

2475 9AB DP - Calibration Measured 9 FP R/W 0.00<br />

2477 9AD DP - Calibration Measured 10 FP R/W 0.00<br />

2479 9AF DP - Calibration Measured 11 FP R/W 0.00<br />

2481 9B1 DP - Calibration Measured 12 FP R/W 0.00<br />

1 The Calibration Type register must be configured using ModWorX Pro. This register defines the type and<br />

number of calibration points used. If altered manually, calibration points must be entered in ascending order.<br />

C-15