Appendix C Scanner ® 2000 microEFM Register (Decimal) C-10 Turbine 2 Configuration Register (Hex) Description 2100 834 T2 - Units See Units Table Data Type Access Default U16 R/W 102 – BBL 2101 835 T2 - Time Base U16 R/W 3 – Day 2102 836 T2 - Sampling Period (sec) U16 R/W 5 2103 837 T2 - Dampening Factor U16 R/W 0 2104 838 T2 - Input Configuration 0 - TFM Low (20 mV @

Scanner ® 2000 microEFM Appendix C Register (Decimal) Register (Hex) Description Turbine 2 Calibration Data Type Access Default 2155 86B T2 - Factor 11 FP R/W 1.00 2157 86D T2 - Factor 12 FP R/W 1.00 2159 86F T2 - Frequency 1 FP R/W 1.00 2161 871 T2 - Frequency 2 FP R/W 1.00 2163 873 T2 - Frequency 3 FP R/W 1.00 2165 875 T2 - Frequency 4 FP R/W 1.00 2167 877 T2 - Frequency 5 FP R/W 1.00 2169 879 T2 - Frequency 6 FP R/W 1.00 2171 87B T2 - Frequency 7 FP R/W 1.00 2173 87D T2 - Frequency 8 FP R/W 1.00 2175 87F T2 - Frequency 9 FP R/W 1.00 2177 881 T2 - Frequency 10 FP R/W 1.00 2179 883 T2 - Frequency 11 FP R/W 1.00 2181 885 T2 - Frequency 12 FP R/W 1.00 1 The Calibration Type register must be configured using ModWorX Pro. This register defines the type and number of calibration points used. If altered manually, calibration points must be entered in ascending order. Register (Decimal) Static Pressure Configuration Register (Hex) Description 2200 898 SP - Units See Units Table Data Type Access Default U16 R/W 301 2201 899 SP - Time Base U16 R/W 0 2202 89A SP - Sampling Period U16 R/W 1 2203 89B SP - Dampening Factor U16 R/W 0 2204 89C SP - Input Configuration U16 R/W 1 2205 89D SP - Override Enable 0 - Disabled 1 - Enabled 2 - Flow Dependent Averaging U16 R/W 2 2206 89E SP - Override Value FP R/W 0.00 2208 8A0 SP - Fail Value FP R/W 0.00 2210 8A2 SP - Low Input Cutoff FP R/W 0.00 2212 8A4 SP - Low Flow Cutoff FP R/W 0.00 2214 8A6 SP - Sensor Range Low FP RO from MVT 2216 8A8 SP - Sensor Range High FP RO from MVT 2218 8AA SP - Units Scale Factor FP R/W 1.00 2220 8AC SP - Units Offset Factor FP R/W 0.00 2222 8AE SP - Unit Description 1 LCD R/W C-11

Appendix C <strong>Scanner</strong> ® <strong>2000</strong> microEFM<br />

Register<br />

(Decimal)<br />

C-10<br />

Turbine 2 Configuration<br />

Register<br />

(Hex) Description<br />

2100 834 T2 - Units<br />

See Units Table<br />

Data<br />

Type Access Default<br />

U16 R/W 102 – BBL<br />

2101 835 T2 - Time Base U16 R/W 3 – Day<br />

2102 836 T2 - Sampling Period (sec) U16 R/W 5<br />

2103 837 T2 - Dampening Factor U16 R/W 0<br />

2104 838 T2 - Input Configuration<br />

0 - TFM Low (20 mV @