<strong>Scanner</strong> ® <strong>2000</strong> microEFM Appendix C<br />

Register<br />

(Decimal)<br />

System Configuration<br />

Register<br />

(Hex) Description<br />

Data<br />

Type Access<br />

1000 3E8 Product Code and Feature Privileges U16 RO<br />

1001 3E9 Register Table Version U16 RO<br />

1002 3EA Firmware Version U16 RO<br />

1003 3EB Manufacture Date U16 RO<br />

1004 3EC Sales Date U16 RO<br />

1005 3ED Serial Number High U16 RO<br />

1006 3EE Serial Number Low U16 RO<br />

1007 3EF Sensor Serial Number[0] PA RO<br />

1008 3F0 Sensor Serial Number[1] PA RO<br />

1009 3F1 Sensor Serial Number[2] PA RO<br />

1010 3F2 Sensor Serial Number[3] PA RO<br />

1011 3F3 Sensor Serial Number[4] PA RO<br />

1012 3F4 Sensor Serial Number[5] PA RO<br />

1013 3F5 Expansion Board Manufacture Date U16 RO<br />

1014 3F6 Expansion Board Sales Date U16 RO<br />

1015 3F7 Expansion Board Serial Number High U16 RO<br />

1016 3F8 Expansion Board Serial Number Low U16 RO<br />

1017 3F9 Expansion Board Configuration U16 RO<br />

Product Code<br />

The Product Code is a read-only parameter used for identifying a <strong>Scanner</strong> <strong>2000</strong> device and its enabled<br />

advanced features (such as PID controller and Modbus Master) using the ModWorX Pro software. This<br />

parameter is defined at the factory.<br />

Firmware Version/Register Table Version<br />

The Firmware Version and Register Table Version numbers are set by the factory and are read-only. To<br />

determine the version number, read the appropriate register and divide the value by 100. The general format<br />

for version numbers is A.BC. For example the firmware register number is read as 0xA7 hexadecimal. This<br />

represents the value 167 and a firmware version of 1.67.<br />

Manufacture Date/Sales Date<br />

These parameters are set at the factory and are read-only. These registers are formatted as MMYY. For<br />

example, a value of 0908 represents the date September 2008.<br />