<strong>Scanner</strong> ® <strong>2000</strong> microEFM Appendix C<br />

Security<br />

To communicate with a <strong>Scanner</strong> <strong>2000</strong> without the use of ModWorX Pro software (i.e. via a third-party polling<br />

device), security permissions for the applicable <strong>Scanner</strong> <strong>2000</strong> communications port must be set to the default<br />

(unrestricted) state. If a different security level is required, contact Cameron technical support for details.<br />

Security levels can be restored to default permissions with ModWorX Pro software.<br />

Registers<br />

Each register has an Access type: read-only or read-write, as described below.<br />

Access Type Description<br />

Read Only (RO) Register can only be read<br />

Read/Write (R/W) Register can be read and written<br />

The registers are grouped into Modbus® map blocks according to function. The <strong>Scanner</strong> <strong>2000</strong> contains the<br />

following map functions.<br />

Map Starting Register<br />

Control Registers 70<br />

System Configuration 1000<br />

Communications Configuration 1100<br />

Real Time 1200<br />

Power Configuration 1300<br />

Archive Configuration 1400<br />

Turbine 1 Configuration <strong>2000</strong><br />

Turbine 1 Calibration 2030<br />

Turbine 2 Configuration 2100<br />

Turbine 2 Calibration 2130<br />

Static Pressure Configuration 2200<br />

Static Pressure Calibration 2230<br />

RTD Configuration 2300<br />

RTD Calibration 2330<br />

Differential Pressure Configuration 2400<br />

Differential Pressure Calibration 2430<br />

Analog Input 1 Configuration 2500<br />

Analog Input 1 Calibration 2530<br />

Analog Input 2 Configuration 2600<br />

Analog Input 2 Calibration 2630<br />

<strong>Flow</strong> Run 1 Configuration 3000<br />

<strong>Flow</strong> Run 1 Calibration 3200<br />

<strong>Flow</strong> Run Alarms 3600<br />

Output Configuration 4000<br />

Holding Registers (32-bit) 7000<br />

Holding Registers 8000<br />

User-Defined Holding Register Configuration 9000<br />

C-3