Spiraflo Steam Flowmeters - Spirax Sarco
Spiraflo Steam Flowmeters - Spirax Sarco
Spiraflo Steam Flowmeters - Spirax Sarco
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
M111 series transducer<br />
Sizes available: DN40, 50, 80, 100<br />
Flanges M111 BS 4504 PN25<br />
BS 10, Table H<br />
JIS 10, JIS 20<br />
ANSI B16.5 Class 150 & 300<br />
M115 BS 4504 PN25<br />
BS 10 Table H<br />
JIS 10, JIS 20<br />
ANSI B16.5 Class 150 & 300<br />
Body materials M111-SG Iron DIN 1693 GGG40<br />
M115-Steel DIN 17245 GSC2<br />
Internal materials - mostly stainless steel<br />
Torsion spring material - nickel cobalt alloy<br />
Gaskets - exfoliated graphite (EFG)<br />
Principle of operation - spring loaded variable area<br />
Flow medium - saturated or superheated steam<br />
Flow capacities - see tables<br />
Maximum operating temperature - 230°C<br />
Maximum operating pressure - 17 bar g<br />
Minimum operating pressure - 1 bar g<br />
Dimensions and weights - see table on page 7<br />
Turndown - 40:1 intermittent, 25:1 continuous<br />
Accuracy a) ± 1 % FSD at 50 % of flow, b) ± 2 % of actual flow<br />
Installation - straight pipe lengths: 6 D upstream, 3 D downstream<br />
(D = normal pipe diameter)<br />
Mounting - horizontal, vertical (flow down) acceptable<br />
M322 signal conditioning unit<br />
The M322 signal conditioning unit accepts temperature and flow signals<br />
from the M111 transducer as well as a 4 - 20 mA analogue pressure<br />
signal from an EL2600 pressure transmitter. These signals are<br />
converted into digital form for onward transmission to the M210G flow<br />
computer which can be located up to 300 m away.<br />
Materials of construction of enclosure - polycarbonate<br />
Dimensions and weights - see table on page 7<br />
Enclosure rating: IP65 (when fitted with suitable cable glands)<br />
Type of mounting: Wall mounting using brackets supplied<br />
Maximum operating temperature: 65°C<br />
Supply voltage - 24 Vdc (from M210G computer)<br />
Channel Input Output<br />
Port 1 Analogue input from Frequency signal<br />
M111 transducer (150 - 1500 Hz) which<br />
proportional to plate is proportional to flow<br />
deflection angle through the M111<br />
(using RVDT) i.e.: flow transducer.<br />
Port 2 Analogue input from Frequency signal<br />
(temperature) Pt100 temperature (150 - 1500 Hz) which<br />
sensor incorporated is proportional to<br />
into M111 transducer measured temperature<br />
Port 3 4 - 20 mA from EL2600 Frequency signal<br />
(pressure) series pressure (150 - 1500 Hz) which<br />
transmitter Max. loop is proportional to<br />
impedance = 150 ohms<br />
Open circuit<br />
voltage = 15 volts<br />
measured pressure<br />
EL2600 pressure transmitter<br />
NB. This is only required for superheated steam applications<br />
Options available for use 0 - 1.6 bar g<br />
with <strong>Spiraflo</strong> 0 - 2.5 bar g<br />
0 - 4.0 bar g<br />
0 - 6.0 bar g<br />
0 - 10.0 bar g<br />
0 - 16.0 bar g<br />
0 - 25.0 bar g<br />
'U' Syphon assembly<br />
Process connection<br />
Mount the EL2600 via a ¼" BSPP connection into the 'U' syphon<br />
assembly and mount the 'U' syphon assembly via a ¼" BSPP connection<br />
directly into the pipework.<br />
Full installation details are supplied with the EL2600.<br />
Maximum pressure<br />
EL2600 - The rated pressures can be exceeded to the following limits<br />
without degrading performance: 3 bar for 1.6 bar g range.<br />
3 times FS (Full Scale) for ranges 2.5 to 25 bar g.<br />
'U' syphon - the 'U' syphon is pressure rated for use with the pressure<br />
transmitters listed above.<br />
Burst pressure<br />
EL2600 only - 50 bar for ranges 0 to 25 bar g.<br />
Maximum temperature<br />
With 'U' syphon - up to 450°C maximum.<br />
Enclosure rating<br />
IP65 to BS 5490 (IEC 529).<br />
Accuracy<br />
0.5 % FSD (including hysteresis, repeatability and thermal error).<br />
Output<br />
2 wire 4 - 20 mA current loop.<br />
Supply - 24 Vdc standard (11 to 33 Vdc operable).<br />
Maximum loop resistance 650 W at 24 Vdc.<br />
Connection via 4 pole plastic connector.<br />
Materials of construction<br />
EL2600 - wetted parts stainless steel plus stainless steel body with<br />
moulded plastic head and connector assembly. 'U' syphon assembly<br />
zinc plated carbon steel tube (BS 1706) with plated carbon steel valve<br />
colour passivated to DEF 130.<br />
Dimensions and weights<br />
See table on page 7.<br />
M210G series flow computer<br />
Function - carry out all signal processing and provide local display of<br />
flow, total, pressure, time and date.<br />
Units of display - metric or imperial. Flow parameters can be<br />
displayed in mass or energy units.<br />
Full density compensation inbuilt.<br />
Customer programmable for steam quality correction.<br />
4 batching timers with peak flow capture.<br />
1 x 8 day repeating timer.<br />
High / low flowrate alarm.<br />
High / low pressure alarm.<br />
High / low temperature alarm.<br />
Battery back-up for clock and flow data.<br />
Access security code protected.<br />
Programmable 4 - 20 mA analogue output for flowrate (kg / h).<br />
Programmable pulse output for total flow kg.<br />
RS232C interface.<br />
Can be located up to 300 m from point of flow measurement.<br />
Supply voltage 110, 220 or 24 Vac (50 / 60 Hz).<br />
Power consumption - less than 15 W.<br />
Enclosure - light / dark grey polycarbonate.<br />
Mounting - wall or panel mount.<br />
Rating IP65 (with suitable cable glands) - NOT panel mount<br />
Maximum ambient temperature: 50°C.<br />
Some of the products shown may not be available in certain markets.<br />
<strong>Spirax</strong>-<strong>Sarco</strong> Limited, Charlton House,<br />
Cheltenham, Gloucestershire, GL53 8ER UK.<br />
Tel: +44 (0)1242 521361 Fax: +44 (0)1242 573342<br />
E-mail: enq@spiraxuk.attmail.com<br />
Internet: www.spirax-sarco.com<br />
© Copyright 1996 <strong>Spirax</strong> <strong>Sarco</strong> is a registered trademark of <strong>Spirax</strong>-<strong>Sarco</strong> Limited<br />
SB-P330-01 MI Issue 4<br />
SFLO