M111 series transducer<br />

Sizes available: DN40, 50, 80, 100<br />

Flanges M111 BS 4504 PN25<br />

BS 10, Table H<br />

JIS 10, JIS 20<br />

ANSI B16.5 Class 150 & 300<br />

M115 BS 4504 PN25<br />

BS 10 Table H<br />

JIS 10, JIS 20<br />

ANSI B16.5 Class 150 & 300<br />

Body materials M111-SG Iron DIN 1693 GGG40<br />

M115-Steel DIN 17245 GSC2<br />

Internal materials - mostly stainless steel<br />

Torsion spring material - nickel cobalt alloy<br />

Gaskets - exfoliated graphite (EFG)<br />

Principle of operation - spring loaded variable area<br />

Flow medium - saturated or superheated steam<br />

Flow capacities - see tables<br />

Maximum operating temperature - 230°C<br />

Maximum operating pressure - 17 bar g<br />

Minimum operating pressure - 1 bar g<br />

Dimensions and weights - see table on page 7<br />

Turndown - 40:1 intermittent, 25:1 continuous<br />

Accuracy a) ± 1 % FSD at 50 % of flow, b) ± 2 % of actual flow<br />

Installation - straight pipe lengths: 6 D upstream, 3 D downstream<br />

(D = normal pipe diameter)<br />

Mounting - horizontal, vertical (flow down) acceptable<br />

M322 signal conditioning unit<br />

The M322 signal conditioning unit accepts temperature and flow signals<br />

from the M111 transducer as well as a 4 - 20 mA analogue pressure<br />

signal from an EL2600 pressure transmitter. These signals are<br />

converted into digital form for onward transmission to the M210G flow<br />

computer which can be located up to 300 m away.<br />

Materials of construction of enclosure - polycarbonate<br />

Dimensions and weights - see table on page 7<br />

Enclosure rating: IP65 (when fitted with suitable cable glands)<br />

Type of mounting: Wall mounting using brackets supplied<br />

Maximum operating temperature: 65°C<br />

Supply voltage - 24 Vdc (from M210G computer)<br />

Channel Input Output<br />

Port 1 Analogue input from Frequency signal<br />

M111 transducer (150 - 1500 Hz) which<br />

proportional to plate is proportional to flow<br />

deflection angle through the M111<br />

(using RVDT) i.e.: flow transducer.<br />

Port 2 Analogue input from Frequency signal<br />

(temperature) Pt100 temperature (150 - 1500 Hz) which<br />

sensor incorporated is proportional to<br />

into M111 transducer measured temperature<br />

Port 3 4 - 20 mA from EL2600 Frequency signal<br />

(pressure) series pressure (150 - 1500 Hz) which<br />

transmitter Max. loop is proportional to<br />

impedance = 150 ohms<br />

Open circuit<br />

voltage = 15 volts<br />

measured pressure<br />

EL2600 pressure transmitter<br />

NB. This is only required for superheated steam applications<br />

Options available for use 0 - 1.6 bar g<br />

with <strong>Spiraflo</strong> 0 - 2.5 bar g<br />

0 - 4.0 bar g<br />

0 - 6.0 bar g<br />

0 - 10.0 bar g<br />

0 - 16.0 bar g<br />

0 - 25.0 bar g<br />

'U' Syphon assembly<br />

Process connection<br />

Mount the EL2600 via a ¼" BSPP connection into the 'U' syphon<br />

assembly and mount the 'U' syphon assembly via a ¼" BSPP connection<br />

directly into the pipework.<br />

Full installation details are supplied with the EL2600.<br />

Maximum pressure<br />

EL2600 - The rated pressures can be exceeded to the following limits<br />

without degrading performance: 3 bar for 1.6 bar g range.<br />

3 times FS (Full Scale) for ranges 2.5 to 25 bar g.<br />

'U' syphon - the 'U' syphon is pressure rated for use with the pressure<br />

transmitters listed above.<br />

Burst pressure<br />

EL2600 only - 50 bar for ranges 0 to 25 bar g.<br />

Maximum temperature<br />

With 'U' syphon - up to 450°C maximum.<br />

Enclosure rating<br />

IP65 to BS 5490 (IEC 529).<br />

Accuracy<br />

0.5 % FSD (including hysteresis, repeatability and thermal error).<br />

Output<br />

2 wire 4 - 20 mA current loop.<br />

Supply - 24 Vdc standard (11 to 33 Vdc operable).<br />

Maximum loop resistance 650 W at 24 Vdc.<br />

Connection via 4 pole plastic connector.<br />

Materials of construction<br />

EL2600 - wetted parts stainless steel plus stainless steel body with<br />

moulded plastic head and connector assembly. 'U' syphon assembly<br />

zinc plated carbon steel tube (BS 1706) with plated carbon steel valve<br />

colour passivated to DEF 130.<br />

Dimensions and weights<br />

See table on page 7.<br />

M210G series flow computer<br />

Function - carry out all signal processing and provide local display of<br />

flow, total, pressure, time and date.<br />

Units of display - metric or imperial. Flow parameters can be<br />

displayed in mass or energy units.<br />

Full density compensation inbuilt.<br />

Customer programmable for steam quality correction.<br />

4 batching timers with peak flow capture.<br />

1 x 8 day repeating timer.<br />

High / low flowrate alarm.<br />

High / low pressure alarm.<br />

High / low temperature alarm.<br />

Battery back-up for clock and flow data.<br />

Access security code protected.<br />

Programmable 4 - 20 mA analogue output for flowrate (kg / h).<br />

Programmable pulse output for total flow kg.<br />

RS232C interface.<br />

Can be located up to 300 m from point of flow measurement.<br />

Supply voltage 110, 220 or 24 Vac (50 / 60 Hz).<br />

Power consumption - less than 15 W.<br />

Enclosure - light / dark grey polycarbonate.<br />

Mounting - wall or panel mount.<br />

Rating IP65 (with suitable cable glands) - NOT panel mount<br />

Maximum ambient temperature: 50°C.<br />

Some of the products shown may not be available in certain markets.<br />

<strong>Spirax</strong>-<strong>Sarco</strong> Limited, Charlton House,<br />

Cheltenham, Gloucestershire, GL53 8ER UK.<br />

Tel: +44 (0)1242 521361 Fax: +44 (0)1242 573342<br />

E-mail: enq@spiraxuk.attmail.com<br />

Internet: www.spirax-sarco.com<br />

© Copyright 1996 <strong>Spirax</strong> <strong>Sarco</strong> is a registered trademark of <strong>Spirax</strong>-<strong>Sarco</strong> Limited<br />