10.07.2015 Views

Service Contract No 2007 / 147-446 - Swaziland

Service Contract No 2007 / 147-446 - Swaziland

Service Contract No 2007 / 147-446 - Swaziland

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Figure 12. Atmospheric pressure vs. height above sea levelThe suction height of PS 1 and PS 2 was measured to be approximately 4 and 3 metersbelow the impellor eye respectively. The NPSH required (NPSHr) of the pumps in this pumpstations is 1.5m and 4.5m respectively (see attached pump curves). PS 3 pumps have anNPSHr of 3 meters. From the above formula the maximum allowable suction height is 7.38m,4.9m and 6.1m for the pumps in the three pump stations respectively. These calculationsconfirm that all pumps were installed with correct suction height.Further analysis compared NPSH available to NPSH required and all pumps in this irrigationscheme conforms to the recommendation of NPSHr

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!