dFigure 4 Required radius of 90 bends (source: ARC (<strong>2007</strong>))r 2d100mm …………………………………... (2)Where: r = radius of bend (mm)d = inner diameter of suction pipe (mm).All 90° bends measured in the three pump stations had a shorter radius than required.200mm 90° bends in PS 1 are 200mm in radius and PS 2 and 3 250mm 90° bends have aradius of 350mm. According to figure 4 and equation 2 above the required minimum radius is500mm and 600mm for the two sizes respectively. However, there is more than five time thesuction and delivery pipe size diameter pipe further on from these bends; the effects of theincorrect sizes are insignificant.Figure 5. 90° suction bendsMaphobeni Farmers Association Report - 2009 Page - 16 -