10.07.2015 Views

RTD Scanner - Axiomatic Technologies Corp.

RTD Scanner - Axiomatic Technologies Corp.

RTD Scanner - Axiomatic Technologies Corp.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Technical SpecificationsInputsPower Supply InputSupply CurrentProtection<strong>RTD</strong> Types<strong>RTD</strong> InputsScan RateCommon Mode ReadingsThermal DriftIsolationSPNs and PGNs12V or 24VDC nominal (9…32 VDC power supply range)200 mA at 12 V Typical100 mA at 24 V TypicalInrush does not exceed 800 mA.Reverse polarity protection is provided.Power supply input section protects against transient surges and short circuitsand is isolated from <strong>RTD</strong> inputsUp to 8 channels, independently configurable for 2, 3 or 4 wire <strong>RTD</strong>s.Each channel independently supports specific sensors IEC 0.00385, JIS0.003916, US 0.003902, Legacy 0.003920, SAMA 0.003923.A user defined coefficient would enable custom Callendar-Van Dusen constantsto be set for sensors not listed above.The device accepts inputs within the following range of 10 - 350 Ohms.Accuracy: +/- 1°C typical at ambient temperatureResolution: 0.001°CIsolation voltage is 1500 Vac (rms) or 2550V for 1 sec.100ms per channel, total sweep time maximum 900 msInput range +/- 4V maximumRejection is 100db at 5Vp-p (50-60Hz)150 ppm/°C of span (maximum)Digital isolation is 500VDC from input to ground.Three way isolation is provided for the CAN line, inputs and power supplyThe SPN drop list includes all temperature SPNs from the J1939-71 standardpublished up to January of 2009. If an SPN is not supported by the drop list, theuser can select a zero SPN, which then allows them to define the SPN and PGNper the application requirements.One byte parameters have a resolution of 1 °C / bit and a range of -40 °C to 210°C. Two byte parameters have resolution of 0.03125 °C / bit and a range of -273°C to 1735 °C (per SAE J1939).AveragingProtectionCommunicationCANNetwork TerminationRS-232The Parameter Group Number (PGN) that will be used to send a temperature tothe J1939 network will be entirely dependent on the Suspect Parameter Number(SPN) that was selected for that channel. In all cases, the PGN is a PDU2 type.Each PGN has a predefined priority and repetition rate associate with it.The average temperature of all the active channels can be broadcasted to thenetwork using the default “Engine Average Information” PGN, or on a ProprietaryB message.Open circuit detectionFrozen data detectionOver or under temperature detectionHigh temperature shutdown detection1 CAN 2.0B port, protocol SAE J1939Digital isolation is provided for the CAN line.According to the CAN standard, it is necessary to terminate the network withexternal termination resistors. The resistors are 120 Ohm, 0.25W minimum,metal film or similar type. They should be placed between CAN_H and CAN_Lterminals at both ends of the network.1 RS-232 port is available for debugging purposes.ASCII Text Format, 115200 Baud RateData – 8 bit, Parity – None, Stop – 1 bit. Flow Control – Xon/Xoff.Short circuit protection to ground.TDAX<strong>RTD</strong>8 3


PackagingRugged aluminum housing, stainless steel end plates, neoprene gaskets145.30 x 149.00 x 73.00 mm (5.72 x 5.86 x 2.87”) L x W x HConnectors, Deutsch IPD P/N: 1 8-pin DT13-08PA, 1 40-pin DRC13-40PACan be mounted directly on the power generator set or remotelySuitable for moist, high shock, vibrating and non-hazardous environmentsDimensional DrawingElectrical Pin Out – Power and CANTDAX<strong>RTD</strong>8 5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!