10.07.2015 Views

Proposed Renovation of Former Jacinto Building - Clark Freeport Zone

Proposed Renovation of Former Jacinto Building - Clark Freeport Zone

Proposed Renovation of Former Jacinto Building - Clark Freeport Zone

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

High Pressure Plastic Laminate compartments, 12mm thick Phenolic antibacterialwater pro<strong>of</strong> partition, Laminate edges are applied before facelaminate and bonded with a thermo-setting resin glue under continuous heatand pressure. All face laminate are bonded with a polyvinyl acetate adhesive.Including all hardware shall be stainless steel or any approved accepted to thesatisfaction <strong>of</strong> the Engineer.The quantities to be paid for this item shall be the number <strong>of</strong> unit/set installedand accepted by the Engineer.STEEL WINDOWS (Supply and Install)Item 1005 (a) to (b)This item shall consist <strong>of</strong> all fabricated steel windows fully equipped with fixingaccessories and locking devices as shown on the Plans and in accordance withthis specification.All members shall be <strong>of</strong> hot-rolled, low carbon, new billet steel, heavy sectionwith depth <strong>of</strong> at least 33mm and web thickness <strong>of</strong> at least 3mm. Muntins shallbe 25mm by 25mm rolled-tee sections. All members to be used shall conformto the specification requirements <strong>of</strong> ASTM A “505. The frame member shallafford not less than 16mm continuous anchorage to surrounding masonry.Painting <strong>of</strong> metal frames shall conform to item 1032.Glass thickness shall be 6mm for both Awning and Fixed glass window. Verifyall measurement to match actual conditions.The quantities to be paid for shall be the actual area in square meter <strong>of</strong> steelwindows and glass panel satisfactorily installed.STEEL DOORS AND FRAMES (Supply and Install)Item 1005 (a) to (c)This item shall consist <strong>of</strong> furnishing and installing all fabricated steel door andframes equipped with fixing accessories and locking devices in accordance withPlans and/or Specifications.All door cladding plates or panels shall be formed from gauge 20 cold-rolled,prime quality steel. Frames shall be formed from gauge 16 cold-rolled steel.The materials used shall conform with the specification requirement <strong>of</strong> ASTM-A505.Flush doors shall be constructed from outer steel sheet not lighter than gauge20, with edges welded and finished flush. The outer face sheets shall be92<strong>Clark</strong> Development Corporation <strong>Proposed</strong> <strong>Renovation</strong> <strong>of</strong> <strong>Former</strong> <strong>Jacinto</strong> <strong>Building</strong>(Motorpool, Records, Warehouses and Maintenance Area)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!