Any one of the Following:o Computation of Net Financial Contracting Capacity (NFCC) which must be equalto ABC (Sample Form No. SF-INFR 19) , ORoCertificate of commitment specific to the contract to be bid, issued by alicensed bank to extend to the bidder a credit line if awarded the contractwhich shall at least equal to 10% of ABC. (Sample Form No. SF-INFR 20)Class B Documents If applicable, valid Joint Venture Agreement (JVA) or, in lieu thereof, duly notarizedstatements from all the potential joint venture partners stating that they will enterinto and abide by the provisions of the JVA in the instance that the bid is successfulshall be included in the bid.TECHNICAL DOCUMENTS Bid SecurityAny one of the following: Php 356,066.91 (2% of ABC), if bid security is in cash,cashier’s/manager’s check, bank draft/guarantee confirmed by aUniversal or Commercial bank;Php 356,066.91 (2% of ABC), Irrevocable Letter of Credit issuedby a Universal or Commercial Bank: Provided, however, that it shallbe confirmed or authenticated by a Universal or Commercial Bank, ifissued by a foreign bank.Php 890,167.28 (5% of ABC) if bid security is in Surety Bondcallable upon demand issued by a surety or insurance company dulycertified by the Insurance Commission as authorized to issue suchsecurity; orAny combination of the foregoing proportionate to the share of formwith respect to total amount of security.Except for the following CDC blacklisted Insurance Company:Sterling InsuranceStronghold Insurance175
Organizational chart for the contract to be bid; List of contractor’s personnel (viz, Project Manager/ Engineer, Materials Engineer,Electrical Engineer, Sanitary Engineer and Foremen), to be assigned to the contractto be bid, their complete qualifications, Letter to Procuring Entity, Notarized Certificateof Employment, Bio-data and Photocopy of Valid Professional License (forProfessionals) using the following prescribed forms:1. Sample Form INFR-48 : Qualification of Proposed Key Personnelto be assigned to the Contract;2. Sample Form INFR-45 : Contractor’s Letter Certificate toProcuring Entity (for each personnel);3. Sample Form INFR-46 : Notarized Key Personnel’s Certificate ofEmployment (for each personnel); and4. Sample Form INFR-47: Key Personnel Format of Bio-data (foreach personnel) List of contractor’s equipment units, which are owned, leased, and/or under purchaseagreements, supported by certification of availability of equipment from theequipment lessor/vendor for the duration of the project; and Duly Notarized and Accomplished Omnibus Sworn Statement. Duly Signed Bid Bulletin, if applicable.Checklist of Financial Component forBiddersThe Financial Component shall contain one (1) Original and Two (2) Duplicate Copies of thefollowing: Financial Bid Form in accordance with the form prescribed in Section IX BiddingForms; Detailed Estimates including a summary sheet indicating the unit prices ofconstruction materials, labor rates and equipment rentals used in coming up with thebid in the prescribed format (Section VIII Bill of Quantities) Duly Signed Cash Flow and Payment Schedule; and Duly Signed Day Work Schedule.176
- Page 70 and 71: 38. Uncorrected Defects38.1. The Pr
- Page 72 and 73: (c)Include the valuations of approv
- Page 74 and 75: (a)(b)(c)(d)(e)If the Procuring Ent
- Page 76 and 77: unless there are justifiable reason
- Page 78 and 79: consideration and the validity of t
- Page 80 and 81: GCC ClauseSpecial Conditions of Con
- Page 82 and 83: Section VI. Technical Specification
- Page 84 and 85: Item 800 (b) Cleaning and Scrubbing
- Page 86 and 87: in the approved Plan shall undertak
- Page 88 and 89: The concrete materials shall be pro
- Page 90 and 91: The quantity of metal structures to
- Page 92 and 93: Valves for water supply system shal
- Page 94 and 95: High Pressure Plastic Laminate comp
- Page 96 and 97: ALUMINUM GLASS WINDOWS (Supply and
- Page 98 and 99: Doors shall be operated and with pr
- Page 100 and 101: Mortar mixture shall be freshly pre
- Page 102 and 103: portion(s) shall not start until cl
- Page 104 and 105: All panel board and metallic boxes
- Page 106 and 107: Panel boards shall conform to the s
- Page 108 and 109: Section VII. DrawingsSee attached10
- Page 110 and 111: Section VIII. Bill of Quantities108
- Page 112 and 113: Bid FormDate: ___________________IA
- Page 114 and 115: Form of Contract AgreementTHIS Cont
- Page 116 and 117: A C K N O W L E D G E M E N TREPUBL
- Page 118 and 119: 6. [Name of Bidder] is authorizing
- Page 122 and 123: Sample Forms of Eligibility, Techni
- Page 124 and 125: Standard Form Number: SF-INFR-16Sta
- Page 126 and 127: Standard Form Number: SF-INFR-20Rev
- Page 128 and 129: we undertake to pay to the Entity u
- Page 130 and 131: 2) if the Principal does not accept
- Page 132 and 133: Standard Form Number: SF-INFR-45Rev
- Page 134 and 135: Standard Form Number: SF-INFR-46Rev
- Page 136 and 137: Standard Form Number: SF-INFR-47Rev
- Page 138 and 139: Standard Form Number: SF-INFR-48Qua
- Page 140 and 141: DAYWORK SCHEDULEPROJECT : Proposed
Any one <strong>of</strong> the Following:o Computation <strong>of</strong> Net Financial Contracting Capacity (NFCC) which must be equalto ABC (Sample Form No. SF-INFR 19) , ORoCertificate <strong>of</strong> commitment specific to the contract to be bid, issued by alicensed bank to extend to the bidder a credit line if awarded the contractwhich shall at least equal to 10% <strong>of</strong> ABC. (Sample Form No. SF-INFR 20)Class B Documents If applicable, valid Joint Venture Agreement (JVA) or, in lieu there<strong>of</strong>, duly notarizedstatements from all the potential joint venture partners stating that they will enterinto and abide by the provisions <strong>of</strong> the JVA in the instance that the bid is successfulshall be included in the bid.TECHNICAL DOCUMENTS Bid SecurityAny one <strong>of</strong> the following: Php 356,066.91 (2% <strong>of</strong> ABC), if bid security is in cash,cashier’s/manager’s check, bank draft/guarantee confirmed by aUniversal or Commercial bank;Php 356,066.91 (2% <strong>of</strong> ABC), Irrevocable Letter <strong>of</strong> Credit issuedby a Universal or Commercial Bank: Provided, however, that it shallbe confirmed or authenticated by a Universal or Commercial Bank, ifissued by a foreign bank.Php 890,167.28 (5% <strong>of</strong> ABC) if bid security is in Surety Bondcallable upon demand issued by a surety or insurance company dulycertified by the Insurance Commission as authorized to issue suchsecurity; orAny combination <strong>of</strong> the foregoing proportionate to the share <strong>of</strong> formwith respect to total amount <strong>of</strong> security.Except for the following CDC blacklisted Insurance Company:Sterling InsuranceStronghold Insurance175