All panel board and metallic boxes and electrically associated frame works shall begrounded effectively. Conductor and ground wires shall be insulated copper asshown and sizes as indicated in the plans. All connections shall be mechanicallyand electrically sound and secure by split type copper bolts and wire nuts <strong>of</strong>approved type. Grounding wire shall be made <strong>of</strong> stranded copper, s<strong>of</strong>t drawn wireand shall be installed in one continuous length without splices or joint insideconduit. Ground rods shall be made <strong>of</strong> copper-clad steel and shall be driven in fulllength into the earth, sizes <strong>of</strong> which shall be indicated on the Plans’ groundingdetails.WIRES AND WIRING DEVICESItem 1101 (1) to 1101 (29)Wires and cables shall be <strong>of</strong> the approved type meeting all the requirements <strong>of</strong> thePhilippine Electrical Code and bearing the PSA mark. Unless specified or indicatedotherwise, all power and lighting conductors shall be insulated for 600 volts. Allwires shall be copper (unless otherwise specified as seen in the plan), s<strong>of</strong>t drawnand annealed, smooth and <strong>of</strong> cylindrical form and shall be centrally located insidethe insulation.Conductors or wires shall not be drawn in conduits until after the cement plaster isdry and the conduits are thoroughly cleaned and free from dirt and moisture.All joints, taps and splices on wires larger than 14 mm shall be made <strong>of</strong> suitablesolderless connectors <strong>of</strong> the approved type and size. They shall be taped withrubber and PVC tapes providing insulation not less than that <strong>of</strong> the conductors.All wiring devices shall be standard products <strong>of</strong> reputable electrical manufacturers.Wall switches shall be rated at least 16A, 250V and shall be spring operated, flush,tumbler type. Duplex convenience receptacles shall be rated at least 16A, 250V,flush parallel slots. Single heavy duty receptacles shall be rated at least 20A, 250V.3 – wire, flush, polarized type.Auxiliary SystemsAll auxiliary system such as telephone, internet, and fire alarm system installationsshall be done in accordance with the approved design.All materials to be used shall conform to the Bureau <strong>of</strong> Product Standard (BPS)Specifications.102<strong>Clark</strong> Development Corporation <strong>Proposed</strong> <strong>Renovation</strong> <strong>of</strong> <strong>Former</strong> <strong>Jacinto</strong> <strong>Building</strong>(Motorpool, Records, Warehouses and Maintenance Area)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!