316Load application factor for calculation of admissible overhung load on output shaft2.001.801.601.40HZ/PZHC/PC1.20fx 21.000.800.600.400.20R x2 =Rn 2 fx 2An 2 (±)=Rn 2 fa 2 (±)fa 2 (+) fa 2 (-)HZ/PZ 0.74 0.59NHC/NPC 0.86 0.690.00HZ/PZHC/PC0 1 2 3 4 5 6 7 8 9 106.69310.236Distance of load from shaft shoulderXinchAn 2 (±)=Rn 2 fa 2 (±)fa 2 (+) fa 2 (-)FZ 1.04 1.04Permitted overhung load on input shaft(based on input speed n 1 = 1000 rpm <strong>and</strong> theoretical lifetime Lh= 5000 hours).For different operating conditions refer to Par. 12 (c 2 ).6000050000NV07BNV11B40000Rn [lbs]13000020000NV05B10000NV06B001 2 3 45inch235