6.0 - THERMAL CAPACITYP t [HP]«P t » is the horsepower that can be safely transmitted through the gear unit, under a continuousduty <strong>and</strong> at an ambient temperature of 70°F/20°C, without using a supplementary cooling system.Thermals are generally listed within the rating charts along with other key parameters. In thegearmotor rating charts « P t » values are highlighted when the installed horsepower exceeds thethermal rating. Should this be the case, it is recommended that the application is closely investigated<strong>and</strong> that horsepower actually transmitted, without Service Factor, does not exceed the thermalcapacity, after this is adjusted with the applicable factors, « f t » <strong>and</strong> « f v , » depending on ambienttemperature, duty <strong>and</strong> drive speed.Make sure that the following condition is always satisfied:P r1 P t f t f v(4)(A1)t aIntermittent dutyContinuousCyclic duration factorduty[°C] [°F] 80% 60% 40% 20%10 50 1.2 1.3 1.6 1.8 2.020 70 1.0 1.1 1.3 1.5 1.730 85 0.9 1.0 1.2 1.3 1.540 105 0.7 0.8 0.9 1.0 1.250 120 0.5 0.6 0.7 0.8 0.9f tn 1 [rpm]f v750 1.50870 1.301150 1.151450 1.001750 0.902000 0.70Cyclic duration factor is the relationship of operating time under load « t f » to total cycle time (t f +t r ,where « t r » is the time at rest).I tftf tr100 (5)9