Mineralisation and<br />

De-Acidification


Mineralisation and De-Acidification<br />

A post-treatment of desalinated water from evaporators<br />

or RO units is absolutely necessary to get healthy,<br />

potable water. The mineralisation and de-acidification<br />

process inside the <strong>RWO</strong> mineralising units serves to<br />

establish and maintain corrosion inhabiting properties<br />

and slightly increases the hardness.<br />

The application of a mineralising unit has advantages for<br />

crew and passengers, as well as for the equipment material<br />

for distribution, storage and consumers such as airconditions,<br />

ice makers, heating systems etc.<br />

C<br />

D<br />

raw water<br />

Rp a DIN 2999<br />

pure water<br />

Rp a DIN 2999<br />

Type Capacity<br />

m 3 /h<br />

DN c<br />

DIN 2440<br />

B<br />

DN b<br />

DIN 2440<br />

Recomm. Space w/d/h<br />

in mm<br />

G<br />

F<br />

Ø A B C D E F DN b DN c<br />

M-350 0,4-1,0 800/900/2030 350 2030 1720 1840 460 300 25 20<br />

M-450 1,2-2,5 870/1050/2030 450 2030 1740 1860 560 350 25 20<br />

M-550 1,75-3,5 1000/1150/2300 550 2300 2070 2190 665 400 25 20<br />

M-650 2,5-5,0 1070/1300/2350 650 2350 2100 2220 765 450 32 25<br />

All dimensions in mm<br />

drain<br />

l/s<br />

<strong>RWO</strong> GmbH<br />

MArine WAter technology<br />

thalenhorststrasse 15 A<br />

28307 Bremen/germany<br />

Phone: +49 421 537050<br />

Fax: +49 421 53705440<br />

rwo@veoliawater.com<br />

www.rwo.de www.veoliawater.com<br />

E<br />

water becomes potable and shows a considerable<br />

improvement of taste and odour.<br />

water becomes more healthy.<br />

corrosion in the pipes and storage tanks is avoided,<br />

solution of poisonous heavy metals from the<br />

pipe surface in the water is prevented.<br />

ship equipment is protected against corrosion and<br />

subsequent damages.<br />

ø A<br />

The standard capacities of the<br />

<strong>RWO</strong> mineralising units range<br />

from 0,4 m3 /h up to 5 m3 /h as<br />

single filters. Mineralising units<br />

in duplex configuration with two<br />

single filters operating in parallel<br />

mode are also available.<br />

Aktueller Stand: 05/10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!