AlphaCell Broadband BatteriesReplenish and Recycle ProgramBatteries designed specifically for broadband applications.All models deliver 100% "out-of-box" capacity - no cycling required.Premium Gel models offer 50% longer life than traditional gel batteries.Six models incorporating three different battery technologies.Full-replacement, non-prorated warranties.Convenient carrying handle standard on all models.Alpha's standby battery offering includes six different models incorporating three separate battery technologies, ensuringoptimal performance for all Broadband applications. These batteries provide improved performance, longer runtimes andextended service life.


AlphaCell Feature SummaryPremium Gel Gel Premium AGM AGMStandard Warranty 4 and 5 year 4 year 3 year 4 and 5 year 1 year(Optional Extended Warranties available.) full replacement full replacement full replacement full replacement full replacementService Life: Extended Long Long LongRuntime (minutes) 1 : 180, 165 & 85 180 & 165 135 160Sealed VRLA: Valve regulated lead acid Valve regulated lead acid Valve regulated lead acid Valve regulated lead acidHeat Resistant: High High High ModerateHydrogen Emission: Low Low Low LowTerminals 2 : L-type with .28” hole Copper Alloy L-type with .28” hole Copper Alloy 1/4" insert L-type with .28” hole10-32 InsertSpecificationsModel 180 GXL-4/5 165 GXL-4/5 85 GXL 180 GXL-3 165 GXL-3 135 GXL-4/5 160 AGMBattery Type: Silver Alloy Silver Alloy Silver Alloy CA/SN Alloy CA/SN Alloy Silver AlloyTypical Runtime (minutes) 1 : 180 165 85 180 165 135 160Cells Per Unit: 6 6 6 6 6 6 6Voltage Per Unit: 12.8 12.8 12.8 12.8 12.8 12.8 12.8Conductance Value: 1050 1000 1050 1000 1125 1300Max. Discharge Current (A) : 900 800 600 900 800 800 800Short Circuit Current (A): 2600 2500 2200 2600 2500 3100 330010 Second Volts @ 100 Amps: 11.3 11.2 10.8 11.3 11.2 11.5 11.6Ohms Impedance 60 Hz: 0.0050 0.0055 0.0065 0.0050 0.0055 0.005 0.004Capacity at 20 hours: (to 1.75 VPC) 94Ah 86Ah 50Ah 94Ah 86Ah 75Ah 88AhBCI Group size: 31 27 22 31 27 24 27Weight (lbs / kg): 66/ 30 63 / 28.6 39.6 / 18 66 / 30 63 / 28.6 54.8 / 24.9 62 / 28Height w/ terminals (in / mm): 9.48 / 240.8 9.05 / 229.8 8.09 / 205.6 9.48 / 240.8 9.05 / 229.8 8.02 / 203.6 9.05 / 229.8Width (in / mm) 3 : 13.42 / 340.9 12.5 / 317.8 8.99 / 228.3 13.42 / 340.9 12.5 / 317.8 10.26 / 260.5 12.51 / 317.8Depth (in / mm) 3 : 6.80 / 172.7 6.83 / 173.4 5.47 / 138.9 6.80 / 172.7 6.83 / 173.4 6.83 / 173.4 6.83 / 173.4Operating Temperature Range:Discharge (°C): -40° to +71° -40° to +71° -40° to +71° -40° to +71° -40° to +71° -40° to +71° -40° to +71°Charge(with temp compensation)(°C): -23° to +60° -23° to +60° -23° to +60° -23° to +60° -23° to +60° -23° to +60 -23° to +60°Float Charging Voltage (VDC): 13.5-13.8 13.5-13.8 13.5-13.8 13.5-13.8 13.5-13.8 13.5-13.8 13.5-13.8AC Ripple Charger:0.5% RMS or 1.5% of float charge voltage recommended for best results. Maximum allowed = 4% P-P1 Runtimes at 25 Amps to 1.75VPC @ 25°C. No deep discharge cycling required to obtain maximum runtime ratings.2 L-Type: applies to 180/165 GXL and AGM models. Copper Alloy 10-32 Insert: applies to 85 GXL only. Copper Alloy 1/4" insert aplies to 135 GXL only.3 Dimensions at top of battery.Current Discharge Ratings Table in Amps (end Voltage1.75VPC)Hours 1 2 3 4 6 8 10 12 20 24 48 72 100180 GXL 61.2 35.2 25.2 19.7 13.9 10.8 8.9 7.5 4.7 4.0 2.1 1.4 1.03165 GXL 55.9 32.8 23.5 18.4 12.9 10.0 8.2 6.9 4.3 3.7 1.9 1.29 0.94135 GXL 49 28 19.9 15.5 11 8.63 7.1 6.01 3.75 3.15 1.6 1.08 0.7885 GXL 33.2 18.8 13.3 10.4 7.34 5.70 4.68 3.97 2.50 2.12 1.11 0.76 0.56(runtimes based on cable load of 0.9 power factor)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!