10.07.2015 Views

SPEED I QUALITY I AFFORDABILITY

SPEED I QUALITY I AFFORDABILITY

SPEED I QUALITY I AFFORDABILITY

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

www.peerless-lighting.comPeerless makes it easy to bridge speed,quality and affordability.We believe when challenged with alean budget and time constraints,quality lighting should not be exclusiveto the few, rather accessible to all.The Programavailable by requestsee www.peerless-lighting.com for details


QuickShip Products<strong>SPEED</strong> I <strong>QUALITY</strong> I <strong>AFFORDABILITY</strong>Indirect10CRM1QSIndirectT8Indirect7CRM1QSIndirectT5, T5HOIndirectBRM1QSIndirectT5, T5HO, T8C E R R A 7Pg.8LightventLightvent7CRM3QSIndirect/DirectT5, T5HOLouverB R U N OC E R R A 1 0 C E R R A W A L LPg.9Partial PerfBRM4QSBRM7QSPg.12 Indirect/DirectPg.13 Indirect/OpenPg.14T5, T5HO, T8T5, T5HO, T8ID10CRM3QS10CRM4QS10CRM7QSCRW7QSPg.3 Indirect/DirectPg.4 Indirect/Direct Indirect/OpenPg.6 Indirect/OpenPg.7T5, T5HO, T8T5, T5HO, T8T8T5, T5HO, T8IDICM8QSIndirect/DirectT5, T5HO, T8I C E T R A Y C U R V E DPartial PerfDirectICDM8QSDirectT5, T5HO, T8Pg.11Wall Partial PerfPageFixture Options .........................................17 ......................18-19Wiring Details ......................................Typical Applications .......................................22 .............23 ........................................24L I G H T L I N E R E C E S S E DLouverWall WashLSR9QSDirectT5, T5HOLWR9QSDirectT5, T5HO


QuickShip Specification SheetsPEERLESS LIGHTING 2


10CRM4QSspecifications®IDSCEP optionordering logicaluminum end cap optional.white painted perforated steel baffle (PPL). Optional Opal Diffuser (OPD) overlay. 1 ⁄16” for each standard end cap or 4” for each optional sculptured end cap tolonger length fixtures.Sample Catalog Number:10CRM4QS 2 32 WHR SSB 40FT R12 277 GEB10 DCT LP735 F1/18 SCEPlight distribution10”2 5 ⁄8”See Typical Application section forsample layouts.___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________Fixture # of Lamps in Lamp Type Distribution Reflector Shielding Baffle Nominal Maximum Voltage Ballast TypeCross Section Row Length Section Length10CRM4QS 12328T554T5HO32 (T8)(Blank) Standard 65/3520/80 20% Up, 80% Down40/60 40% Up, 60% Down0/100 0% Up, 100% DownCLI 1 Center Lamp IsolaterWHR WhiteReflectorSPR SpecularReflector(Blank) No opaloverlayOPD Baffle w/Opal overlaySSBSBLPPLSemiSpecularBaffleWhiteBladeBaffleWhitePerforatedBladeBaffle____FTMust be in 4’incrementsR4 4’R8 8’R12 12’120277GEB10


®PARTIAL PERFSCEP option10CRM7QSspecificationsaluminum end cap optional. 1 ⁄16” for each standard end cap or 4” for each optional sculptured end cap tolonger length fixtures.ordering logic Sample Catalog Number: 10CRM7QS 2 32 WHR 40FT R12 277 GEB10 DCT LP735 F1/18 SCEP(2,3,4) T8light distribution10”2 5 ⁄8”See Typical Application section forsample layouts.___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________Fixture # of Lamps in Lamp Type Reflector Nominal Maximum Voltage Ballast Type # of Emergency ModulesCross Section Row Length Section Length10CRM7QS 23432 (T8) WHR White ReflectorSPR Specular Reflector____FTMust be in 4’incrementsR4 4’R8 8’R12 12’120277GEB10


CRW7QS®WALL PARTIAL PERFSCEP optionspecificationsaluminum end cap optional. 1 ⁄16” for each standard end cap or4” for each optional sculptured end cap to determine total fixture length. Using internal joiners,light distribution7 5 ⁄8”2 11 ⁄16”See Typical Application section forsample layouts.ordering logic Sample Catalog Number: CRW7QS 1 54T5HO WHR 40FT R12 277 GEB10 SCT LP835 C210 SCEP___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________Fixture # of Lamps in Lamp Type Reflector Nominal Maximum Voltage Ballast Type # of Emergency ModulesCross Section Row Length Section LengthCRW7QS 1228T554T5HO32 (T8)WHR White ReflectorSPR Specular Reflector____FTMust be in 4’incrementsR4 4’R8 8’R12 12’120277GEB10


7CRM1QS7 ® INDIRECTSCEP optionspecificationsaluminum end cap optional.— Pre-painted white steel. 1 ⁄16” for each standard end cap or 4” for each optional sculptured end cap tolonger length fixtures.7 1 ⁄8”light distributionI2 5 ⁄16”See Typical Application section forsample layouts.ordering logic Sample Catalog Number: 7CRM1QS 2 54T5HO WHR 36FT R12 277 GEB10 SCT LP835 C210 F1/21___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________Fixture # of Lamps in Lamp Type Reflector Nominal Maximum Voltage Ballast Type # of Emergency ModulesCross Section Row Length Section Length7CRM1QS 12328T554T5HOWHR White ReflectorSPR Specular Reflector____FTMust be in 4’incrementsR4 4’R8 8’R12 12’120277GEB10


7CRM3QS7 ® LIGHTVENTSCEP optionspecificationsaluminum end cap optional.— Parallel white painted steel baffles. Die-punched perforations on upper housing withacrylic opal diffuser overlay.— Pre-painted white steel. 1 ⁄16” for each standard end cap or 4” for each optional sculptured end cap tolonger length fixtures.7 1 ⁄8”light distribution2 5 ⁄16”See Typical Application section forsample layouts.ordering logic Sample Catalog Number: 7CRM3QS 2 54T5HO WHR 36FT R12 277 GEB10 SCT LP835 C210 F1/21___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________Fixture # of Lamps in Cross Lamp Type Reflector Nominal Maximum Voltage Ballast Type # of Emergency ModulesSectionRow Length Section Length7CRM3QS 12328T554T5HOWHR White Reflector____FTMust be in 4’incrementsR4 4’R8 8’R12 12’120277GEB10


ICM8QSIceTray®CURVED INDIRECT/DIRECTordering logicspecificationsdie-cast aluminum end cap.Sample Catalog Number: ICM8QS 2 28T5 24FT R12 120 GEB10 DCT LP835 C041 F2/24___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________Fixture # of Lamps in Cross Lamp Type Distribution 1 Shielding Nominal Maximum Voltage Ballast TypeSectionRow Length Section Lengthlight distribution10 1 ⁄2”3 1 ⁄8”See Typical Application section forsample layouts.ICM8QS 1 (T5/T5HO only)23428T554T5HO32 (T8)(Blank) 80/20 with T5/T5HO70/30 with T850/50 2 50% Up, 50% Down40/60 3 40% Up, 60% Down30/70 2 30% Up, 70% Down5/95 4 5% Up, 95% Down(Blank) No opal overlayOPD Baffle w/ Opal overlay____FTMust be in 4’incrementsR4 4’R8 8’R12 5 12’120277GEB10


IceTray®with SBPICDM8QSCURVED DIRECTwith OPDspecificationswith die-cast aluminum end cap.cross-section only).7 1 ⁄8” 7 1 ⁄8” Shown with SBPShown with OPDlight distribution3 13 ⁄16” 3 13 ⁄16”See Typical Application section forsample layouts.Dordering logicSample Catalog Number:ICDM8QS 1 54T5HO OPD 28FT R12 277 GEB10 SCT LP835 C041 F1/24 ACG___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________Fixture Ceiling Type # of Lamps in Lamp Type Shielding Nominal Maximum Voltage Ballast TypeCross SectionRow Length Section LengthICDM8QS(Blank) SuspendedS SurfaceMounted1228T554T5HO32 (T8)SBP Side Perforated ShieldOPD 1 Baffle w/ Opal overlay____FTMust be in 4’incrementsR4 4’R8 8’R12 12’120277GEB10ACNS 2OSPSOS10IS 2,3


BRM1QSBruno®INDIRECTspecificationsend cap. 3 ⁄8 ⁄8” for each standard end cap or 4” for each optional sculptured end cap to determine total8 1 ⁄4”light distribution1 11 ⁄16”See Typical Application section forsample layouts.SCEP optionIordering logicSample Catalog Number: BRM1QS 2 28T5 SPR 24FT R8 120 GEB10 SCT LP835 C210 F1/21___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________Fixture # of Lamps in Cross Section Lamp Type Reflector NominalMaximumVoltageBallast TypeRow Length Section LengthBRM1QS 12328T554T5HO32 (T8)SPR Specular Reflector ____FTMust be in 4’incrementsR4 4’R8 8’120277GEB10ACNS 1OSPS 1OS10IS 1,2


Bruno®BRM4QSLOUVERspecificationsend cap.8 1 ⁄4”1 11 ⁄16”1⁄2” 3 ⁄8 ⁄8” for each standard end cap or 4” for each optional sculptured end cap to determine totallight distributionSee Typical Application section forsample layouts.SCEP optionordering logicSample Catalog Number: BRM4QS 2 28T5 SPR 40FT R8 277 GEB10 DCT LP835 C210 SCEP F1/18___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________Fixture # of Lamps in Lamp Type Distribution Reflector Shielding Baffle Nominal Maximum Voltage Ballast TypeCross Section Row Length Section LengthBRM4QS 12328T554T5HO32 (T8)(Blank) Standard 65/3540/60 40% Up, 60% Down20/80 20% Up, 80% Down0/100 0% Up, 100% DownCLI 1 Center Lamp IsolaterSPRSpecularReflector(Blank) No opaloverlayOPD Baffle w/Opal overlaySSBSemiSpecularBaffle____FTMust be in 4’incrementsR4 4’R8 8’120277GEB10ACNS 2OSPS 2OS10IS 2,3


Lightline®RECESSED LOUVER AND WALL WASHordering logic___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________Fixture Ceiling Type # of Lamps in Lamp Type BaffleReflectorMaximum Voltage Ballast TypeCross Section (LSR9 only)(LWR9 only)Section LengthLSR9QSLWR9QSGLay ingridLOUVERWALL WASHLSR9QS & LWR9QSspecificationsSample Catalog Number:1 14T5 14W 2’ T528T5 28W 4’ T524T5HO 24W 2’ T5HO54T5HO 54W 4’ T5HOLSR9QS G 1 54T5HO LDL U4 120 GEB10 LP835LDL Low Iridescent Louver HOL Black Metal DiffuserRound HolesU2 2’U4 4’1202773 1 ⁄2”light distributionD3 3 ⁄4”LSR9QSGEB10


AdditionalInformationFixture Options ................................................................17 ..........................18-19Wiring Details ..........................................................Typical Applications .......................................................................22 .................23Wall Wash ......................................................................... 24PEERLESS LIGHTING 16


Fixture OptionsGENERAL OPTIONSDU Clear plastic dust cover.MOUNTING OPTIONSACG Adjustable Cable Gripper. Allows you to shorten overall suspension to obtain custom lengths.ELH All emergency lighting modules powered by through wire (current load permitting) to oneemergency power feed located at the last support point in the fixture run. See Wiring Details for moreinformation.ELS All emergency and normal lighting powered at the first support/power feed in the fixture run(current load permitting). Emergency and normal share a common neutral. See Wiring Details formore information.OAS = Overall SuspensionELS2 All emergency and normal lighting powered at the first support/power feed in the fixture run(current load permitting). Emergency and normal power provided with separate neutrals. This optionrequires a separate J-Box (by others) for emergency power on “F1” grid ceiling mounts. See WiringDetails for more information. GLR Fusing (fast-blow). Electronic ballasts contain inherent electrical protection. Select GLR if code orregulation requires externally fused ballasts.GMF Fusing (slow-blow). Electronic ballasts contain inherent electrical protection. Select GMF if codeor regulation requires externally fused ballasts.SCEP Sculptured End Cap. Please see product spec sheets for availability.CP Chicago Plenum. Fixtures will be shipped compliant with Chicago Plenum code requirementsMCS Matching Canopy at Support. Increases the canopy diameter on support locations to match thedefault power feed canopy diameter. For F1 that’s 3.5” in diameter and for F2 it’s 5.0” in diameter.OJB Offset J-box at support/power feed location. Our standard support/power feed kit combines thesupport cable and power feed cable into one connection at the ceiling. OJB option instead provides asupport connection separated from the power feed cable at the ceiling, as well as two additional feetof power cable. PEERLESS LIGHTING 17


F1 and F1A Mounting TypeF1 for use with most T-bar and screw slot grid ceiling applications. Mountingdesigned for on-grid and off-grid installations.F1A for use with most T-bar and screw slot grid ceilings applications. Designedfor on-grid and off-grid installations. F1A comes complete with vertical junctionbox with built in wire way.F1 AND F1AMOUNTING TYPEOn-gridFEED SUPPORTF1 AND F1AMOUNTING TYPEOff-gridFEED SUPPORTPEERLESS LIGHTING 18


F2 Mounting TypeF2 for use with hard ceiling applications with recessed or surface mounthorizontal j-box.F2MOUNTINGTYPEFEED (RECESSED) SUPPORT FEED (SURFACE MOUNT)PEERLESS LIGHTING 19


Wiring DetailsSWITCHING OPTIONSSCT Single Circuit. All lamps are wired to a single circuit.DCT Dual Circuit. Two light levels are achieved by switching separate rows of lamps in the samefixture on two independently switched circuits. Dual circuit fixtures share a common neutral.For fixtures or runs with 2 lamps in the cross section the standard DCT circuiting is one side wired tocircuit “A” and the other side wired to a circuit “B”.EL LUMEN OUTPUT PER 1-LAMP EMERGENCY BATTERY PACKLamp Type 32W T8 28W T5 54W T5HOLumens 700 800 825ELEL The default DCT for a fixture with 3 lamps (or more) in the cross section is the row of lamps onthe outside wired to a switched circuit “A” and the lamps located in the middle wired to a switchedcircuit “B”. EMERGENCY LIGHTING OPTIONSNumber of Emergency Modules1SE 1 Section. One 4FT module per run will have an Emergency Lighting option.2SE 2 Sections. Two 4FT modules per run.The standard maximum number of 4FT emergency modules is one per 4 / 8 /12 foot fixture section.Emergency TypeEL Emergency Battery Pack. Each battery pack will be connected to one lamp unless otherwise specified.EC Emergency Circuit. Each emergency/night light circuit will be connected to a single lamp whenonly one lamp is in the cross section. When two or more lamps are in the cross section the two mostouter lamps will be connected to emergency circuit.EC EC EC ECEC EN Emergency Battery Pack with emergency/night light circuit. The same lamp connections applyas emergency circuit, but when only battery power is available then the lamp connections stated foremergency battery pack apply.ECECECECECEC ECECECECEL EL EL EL EL EL PEERLESS LIGHTING


Wiring DetailsEMERGENCY WIRING OPTIONS (No option) Each emergency lighting section is powered at the support point that follows it. ELH Current load permitting, all emergency lighting modules are powered by through wire to oneemergency power feed located at the last support point in the fixture run.ELEL ELS Current load permitting, all emergency lighting modules are powered by a continuous throughwire to one emergency power feed location. The emergency lighting power feed is located at thefirst support point in the fixture run, often combined within the normal power feed cable sharing acommon neutral. Check local electrical code for compliance.ELS2 Same concept as ELS, with the addition of a separate neutral. This option sometimes requires aseparate J-box for emergency power with “F1” grid ceiling mounts.MAXIMUM RUN DISTANCEPER POWER FEEDLamps in Cross SectionLamp Type 120V 277V 347V1 T5HO 56' 124' 160'2 T5HO 28' 64' 80'3 T5HO 16' 40' 52'4 T5HO 12' 32' 40'1 T5 and T8 104' 240' 292'2 T5 and T8 52' 120' 148'3 T5 and T8 36' 80' 96'4 T5 and T8 24' 60' 72'Assumptions: Single circuit, noemergency lighting option, T8 .88 BFballast and T5/T5HO 1.0 BF ballast.Consult factory for other scenarios.EXAMPLE RUNS PEERLESS LIGHTING 21


Application32’40’T8 LAMPS2.5’ Work Plane CeilingAverageUniformity UniformityIlluminance (max:min) (max:min) 3.1:1 49 fc 8.2:1 38 fc 11.7:1 47 fc 3.7:1 9.3:1 47 fc 9.4:1 37 fc 3.3:1 48 fc 4.2:1 7.7:1 46 fc 6.3:1 1.3:10.69 LLF (light loss factor) includes:12’60’For specific application questions, please emailT5 LAMPS2.5’ Work Plane CeilingAverageUniformity UniformityIlluminance (max:min) (max:min) 49 fc 3.3:1 4.4:1 46 fc 3.3:1 48 fc 3.3:1 8.9:1 49 fc 3.4:1 9.1:1 3.7:1 8.8:1 4.4:1 47 fc 3.8:1 8.1:1 6.2:1 1.3:10.79 LLF (light loss factor) includes:1.1 watts per square footT5HO LAMPSPEERLESS LIGHTING 2.5’ Work Plane CeilingAverageUniformity UniformityIlluminance (max:min) (max:min) 43 fc 3.4:1 47 fc 3.9:1 41 fc 3.3:1 9.6:1 47 fc 3.2:1 7.7:1 44 fc 3.3:1 3.2:1 8.4:1 3.3:1 6.1:1 3.3:1 1.4:10.79 LLF (light loss factor) includes:61 total input watts22


Application10’8’For specific application questions, please email12’T8 LAMPS2.5’ Work PlaneAverageIlluminanceMaximumIlluminanceUniformity(max:min) 29 fc 39 fc 37 fc 62 fc 2.8:1 36 fc 1.4:1 39 fc 1.8:1 2.7:1 32 fc 39 fc 29 fc 46 fc 2.4:1 33 fc 3.2:1T5 LAMPS2.5’ Work PlaneAverageIlluminanceMaximumIlluminanceUniformity(max:min) 36 fc 43 fc 1.4:1 36 fc 2.3:1 36 fc 42 fc 1.4:1 29 fc 39 fc 1.7:1 38 fc 1.4:1 29 fc 39 fc 1.7:1 31 fc 61 fc 1.8:1 42 fc 0.69 LLF (light loss factor) includes:(2) T8 lamps:(3) T8 lamps:0.79 LLF (light loss factor) includes:1.1 watts per square foot1.6 watts per square foot97 total input wattsT5HO LAMPSPEERLESS LIGHTING 2.5’ Work PlaneAverageIlluminanceMaximumIlluminanceUniformity(max:min) 43 fc 1.4:1 32 fc 49 fc 2.3:1 42 fc 1.4:1 42 fc 48 fc 1.3:1 67 fc 1.7:1 43 fc 1.4:1 67 fc 1.7:1 33 fc 44 fc 1.9:1 48 fc 68 fc 1.9:1 34 fc 3.3:1 0.79 LLF (light loss factor) includes:61 total input watts121 total input watts23


ApplicationWall WashFor specific application questions, please emailLWR9QS 2’Ceiling Height8’ 9’ 10’ 11’ 12’Average Illuminance 19 fc 16 fc 16 fc 13 fc 14 fc 31 fc 31 fc 31 fc 31 fc 8 fc 7 fc 4 fc 4 fcUniformity (max:min) 3.9:1 4.4:1 6.2:1 7.8:1 LWR9QS 4’Ceiling Height8’ 9’ 10’ 11’ 12’Average Illuminance 44 fc 37 fc 37 fc 31 fc 32 fc 72 fc 71 fc 72 fc 71 fc 19 fc 12 fc 8 fcUniformity (max:min) 3.8:1 4.7:1 6.1:1 7.1:1 0.84 LLF (light loss factor) includes:0.84 LLF (light loss factor) includes:LWR9QS 2’ LWR9QS 4’PEERLESS LIGHTING 24


PEERLESS LIGHTING

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!