Process PumpAutomatically Operated Type<strong>Series</strong> <strong>PAF</strong>SpecificationsOperation methodPortsizeModelDischarge flow rateAverage discharge pressurePilot air pressureAir consumptionSuctionliftNoiseWithstand pressureService lifeOperating fluid temperatureAmbient temperatureRecommended operation cycleWeight (without foot bracket)MountingPackagingMain fluid: Suction/Discharge portPilot air: Supply/Exhaust portDryWet<strong>PAF</strong>3410Automatically operatedRc, G, NPT 1/4"1 to 20 l/min Note)80 dB (A) or less(Option: with silencer, AN200)Note) Values in the table are measured at room temperature using clean water.—1.6 kgRc, G, NPT 3/8" female thread, 1/2" tube extension0 to 0.4 MPa0.2 to 0.5 MPa (for 0 to 60°C)230 l/min (ANR) or lessUp to 1 m (inside the pump is dry)Up to 4 m (with fluid inside the pump)0.75 MPa50 million cycles (for water)0 to 90°C (with no freezing)0 to 70°C (with no freezing)Horizontal (mounting on the bottom surface)Clean double packaging<strong>PAF</strong>3413Air operatedRc, G, NPT 1/8"1 to 15 l/min Note)80 dB (A) or less(excluding the noise from the quick exhaustand solenoid valve)2 to 4 Hz1.3 kg3