10.07.2015 Views

Series PAF - SMC

Series PAF - SMC

Series PAF - SMC

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Related ProductsRelated ProductsWater separator<strong>Series</strong> AMGThe AMG series is installed in air pressurelines to remove water droplets from compressedair. It is suitable for use in cases wherewater must be removed, but the air does nothave to be as dry as that for when an air dryeris used. It may also be used when a powersupply for an air dryer is not available, etc.ModelModel AMG150 AMG250Rated flow Note)(l /min (ANR))300 750Port size(Nominal size B)1/8, 1/4, 3/8 1/4, 3/8, 1/2Weight (kg)0.38 0.55Note) Maximum flow rate at pressure 0.7 MPaRefer to “Best Pneumatics” catalogue for further details.SpecificationsFluidCompressed airMax. operating pressure 1.0 MPaMin. operating pressure Note) 0.05 MPaProof pressure1.5 MPaAmbient and fluid temperature 5 to 60°CDehumidification rate99%2 years, or when theElement service lifepressure drop reaches 0.1 MPa.Note) 0.15 MPa with auto drain.Membrane air dryer<strong>Series</strong> IDGMacromolecular membrane dryersthat act like filtersStandard Specifications/Single Unit (Standard Dew Point –20°C)Range of operatingconditionsStandard performance conditions Standard performanceModelStandard dew point: –20°CIDG5 IDG10 IDG20 IDG30 IDG50FluidCompressed airInlet air pressure(MPa)0.3 to 0.85 0.3 to 1.0Inlet air temperature (°C) Note 1) –5 to 55–5 to 50Ambient temperature (°C)–5 to 55–5 to 50Outlet air atmosphericpressure dew point (°C)–20Inlet air flow rate(l/min (ANR))Note 2)Outlet air flow rate(l/min (ANR))Purge air flow rate(l/min (ANR))Note 3)Inlet air pressure(MPa)Inlet air temperature (°C)Inlet air saturation temperature (°C)Ambient temperature (°C)Dew point indicator purge air flow ratePort size (Nominal size B)Weight (kg)(with bracket)62 125 250 375—1/8, 1/40.25(0.31)0.72525251 l/min (ANR)1/4, 3/862550 100 200 300 50012 25 50 75 1250.43(0.51)0.66(0.76)0.74(0.87)0.77(0.90)Note 1) No freezingNote 2) ANR represents the flow rate converted to the value under 20°C at atmospheric pressure.Note 3) Including the dew point indicator purge air flow rate of 1 l/min (ANR) (inlet air pressure at 0.7 MPa)(Except for IDG5)Refer to “Best Pneumatics” catalogue for further details.Maintenance Parts List<strong>PAF</strong>3410/Automatically Operated TypeDiaphragm kit (PTFE) KT-<strong>PAF</strong>3-31Check valve kitKT-<strong>PAF</strong>3-36Switching valve parts kit KT-<strong>PAF</strong>3-37Pilot valve kitKT-<strong>PAF</strong>3-38Water leakage sensor KT-<strong>PAF</strong>3-47<strong>PAF</strong>3413/Air Operated TypeDiaphragm kit (PTFE)Check valve kitWater leakage sensorKT-<strong>PAF</strong>3-31KT-<strong>PAF</strong>3-36KT-<strong>PAF</strong>3-4714

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!