PMX400 Four Digit Programmable Display with Outputs

PMX400 Four Digit Programmable Display with Outputs

PMX400 Four Digit Programmable Display with Outputs

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Data Sheet • Mann Series<strong>Four</strong> <strong>Digit</strong>, <strong>Programmable</strong> <strong>Display</strong>s<strong>with</strong> Alarms and Analogue Output<strong>PMX400</strong>TMP Temperature <strong>Display</strong><strong>PMX400</strong>HZX Frequency <strong>Display</strong>/Tachometer• Bright four digit LED display in engineeringunits• Up to 4 alarm channels• Optional analogue output• AC or DC powered• Fully Isolated• LED alarm status indication• 1/8 DIN standard front <strong>with</strong> IP65 rating• Integral power supply for active inputdevices• Indicate and change setpoints inengineering units• Full on–site programming from the frontpanel keypad% \AustraliaWeidmüller Pty Ltd.43 Huntingwood Drive, HuntingwoodNSW 2148Phone +61 (0) 2 9671 9999Fax +61 (0) 2 9671 9900Info@weidmuller.com.auwww.mannseries.comUnited KingdomWeidmüller Ltd.1 Abbey Wood Road, Kings HillWest Malling, Kent ME19 4YTPhone +44 1732-877032Fax +44 1732-873873Info@weidmuller.co.ukwww.weidmueller.comOther countriesWeidmüller Interface GmbH & Co.Postfach 303032720 DetmoldPhone +495231-14-0Fax +495231-14-2083info@weidmueller.comwww.weidmueller.com


<strong>PMX400</strong> Series <strong>Display</strong>s<strong>PMX400</strong> SeriesThe <strong>PMX400</strong> series consists of twomodels:• Temperature display• Frequency display/TachometerEach model supports a wide variety of inputsignal types and ranges.The analogue and alarm outputs areoptional, except for the HZX which comes<strong>with</strong> two open collector alarms as standard.Units can be ordered <strong>with</strong> two or four SPDTrelay channels.Alarm channel four can be set up as agroup/siren alarm which operates accordingto the state of the other three alarms.Note: if your process measurement isrepresented by a current or voltage signalyou may be interested in the PMX420 Seriesdisplays. -2700 General Technical Data<strong>Display</strong>TypeFull 4 digit, red 14.2 mm LEDScalingTo display in % or engineering units<strong>Display</strong> range –9999 to 9999Status indicatorsAlarm ch 1–4 and key statusAnalogue output (optional)TypeAnalogue current/voltageScalingTo represent any portion of the input rangeRangeAny range inside the limits 0–22 mA or 0–11 VCurrent driveUp to 850Ω load (at 20mA)Voltage driveTrue voltage source (up to 20mA)Output rippleLess than 20mV P/POutput actionDirect/reverseInput filteringType<strong>Digit</strong>al fi lter (programmable)Damping factor 1 to 99 (default = 2)GeneralAccuracyTypically ±0.1% of spanLinearity Better than 0.05%Repeatability±0.02% of spanTemperature driftLess than 0.02% span/°CLong term drift0.1% per 10,000 hoursFrequency response–3dB point = 5HzResponse time 300 mS for 10–90% output change (digital fi ltering = 1)Insulation Co-ordinationPortsInput / Output / CaseRated Insulation Voltage300VeffOvervoltage CategoryIIIImpulse Withstand 4kV (1.2 / 50)Environmental ConditionsOperating temperature 0 to 60 °CStorage temperature –25 to +70 °CPollution Degree 2Relative humidity10–90% (non–condensing)HousingTypePanel mountFront bezel1/8 DIN format <strong>with</strong> IP65 ratingApprovals Mark StandardDC Powered Units only E205105 CAN/CSA C22.2 No. 142-M1987, 1st Edition\UL508, 17th EditionDC Powered Units only LV Directive EN50178:1998%EMCBS EN 61326:1998 + A2General set–up menu options<strong>Display</strong>HIBr <strong>Display</strong> brightness High or Lowdp= <strong>Display</strong> Decimal Point 0.000 to 0000dLO= <strong>Display</strong> low [Value]dHI= <strong>Display</strong> high [Value]InputsIp=1 Input type See individual unitsIPL= Input range low [Value]IPH= Input range high [Value]dF=2 Input fi ltering 1 to 99Analogue outputAOPY Analogue Output Enable/disableOPL= Output low [Value]OPH= Output high [Value]OP=d Output sense Direct or reversedAlarms 1–4 (general options)A12y Alarms 1 & 2 Enable/disableA34y Alarms 3 & 4 Enable/disableSECy Setpoint security On–the–fl y–changesor lockednOr Alarm reset mode Manual or AutomaticAlarm options (set for each channel)A1nE Output CoilenergisationNormally Energisedor De–energiseda1=H Alarm Type High/Low (and Siren/Group for channelfour only)SP1=50.00db1=10.00dl1=20Setpointe.g., 50.00 unitsIntroduces deadbande.g., 10.00 unitsAlarm Timer Delaye.g., 20 secondsAccording to displayrangeFrom 1 count todisplay range0–4200s(default = 0s)Page 2 Subject to technical alterations <strong>with</strong>out notice • Printed in Australia • 7940015660 • 05/05/2009


<strong>PMX400</strong> Series <strong>Display</strong>sUniversal Temperature Indicator<strong>PMX400</strong>TMP• Accepts thermocouple, RTD or mVinputs• Total sensor diagnostics• Indicates temperature in °C or °F• Confi gure <strong>with</strong>out the need to calibrate• Indicates setpoints in °C or °F• Automatic CJC for thermocouple inputs• Automatic lead length compensation forRTD inputsOptionsThe basic software will control the optionalanalogue outputs and alarm channels<strong>with</strong>out modification. So, to retrofit anoption, you can simply add a card, calibrateand setup for your installation from the frontpanel.%\Technical Data<strong>Display</strong>ScalingInputsTypeStandard ranges:J Type ThermocoupleK Type ThermocoupleN Type ThermocoupleT Type ThermocoupleE Type ThermocoupleB Type ThermocoupleS Type ThermocoupleR Type ThermocouplemV signalsRTD (Pt100)Cold junction compensation for thermocouple inputsLead length compensation for RTD inputsPower supplyTypeAC (selectable)DCPower usageAlarm ouputs (all channels)TypeRatingIsolationGeneralSampling rateOptions/AO/4RONotesOrdering InformationTo display in °C, °F or mVThermocouple, PT100 RTD or mVAny range inside limits shown (no recalibration required)–50°C (–58°F) to 870°C (1598°F)–50°C (–58°F) to 1372°C (2502°F)–50°C (–58°F) to 1300°C (2372°F)–50°C (–58°F) to 400°C (752°F)–50°C (–58°F) to 700°C (1292°F)0°C (32°F) to 1820°C (3308°F)–50°C (–58°F) to 1768°C (3214°F)–50°C (–58°F) to 1768°C (3214°F)–200.00mV to 200.00mV–220.0°C (–364.0°F) to 820.0°C (1508.0°F)AutomaticAutomaticAC or DC powered100 – 132 Vac (47–63Hz) or200 – 264 Vac (47–63Hz)20–28Vdc (others on request)AC 6VA or 6W at 24VdcSPDT relay contacts3A at 240Vac (resistive)3A at 24Vdc (resistive)1kV between channels5 samples per secondWith analogue output fi ttedWith all alarm channels fi ttedType(Model Supply/Options)Cat. No.<strong>PMX400</strong>TMP 24Vdc 7940017862<strong>PMX400</strong>TMP 24Vdc/4RO/AO 7940012968For other ranges please specify <strong>PMX400</strong>TMP 1/2 where:1 = Supply and 2 = OptionsConnectionsTerminal Signal1 Neutral / −Power supply2 Live / +3 Output +4 Current −Analogue output(/AO option only)5 Voltage −67Security LinkSecurity LinkLink to allow access tothe set-up mode (normallynot connected)89CJC Board (white mark10alligns <strong>with</strong> terminal 11)1112 Not used8Not used910 B11 B sense12 A8Not used910 mV input −11 mV input +12 Not used13 Normally Closed14 Common15 Normally Open16 Normally Closed17 Common18 Normally Open19 Normally Closed10 Common21 Normally Open22 Normally Closed23 Common24 Normally OpenThermocouple inputsRTD inputsMillivolt inputsAlarm Channel One(/4RO option only)Alarm Channel Two(/4RO option only)Alarm Channel Three(/4RO option only)Alarm Channel <strong>Four</strong>(/4RO option only)Page 3 Subject to technical alterations <strong>with</strong>out notice • Printed in Australia • 7940015660 • 05/05/2009


<strong>PMX400</strong> Series <strong>Display</strong>sUniversal Frequency Indicator/Tachometer<strong>PMX400</strong>HZX• Measures frequency of signals fromindustrial sensors• Provides power for active input devices• Two alarm channels• Debounce for contact closure inputsOptionsThe basic software will control the optionalanalogue outputs and alarm channels<strong>with</strong>out modification. So, to retrofit anoption, you can simply add a card, calibrateand setup for your installation from the frontpanel.InputsInputs can be taken from many sources,including:• NAMUR sensors• 3–wire PNP/NPN sensors• PNP/NPN open collector outputs• TTL logic• Solid State Switches• Low and high voltage pulses• Volt–free contacts%\Technical Data<strong>Display</strong>ScalingInputsTypeRangeSensor power outputInput voltage rangePower supplyTypeAC (selectable)DCPower usageAlarm ouputs (channels one and two)TypeOperationRatingIsolationAlarm ouputs (channels three and four)TypeRatingIsolationGeneralResponse timeOptions/AO/RO/FPSTo display in engineering units<strong>Programmable</strong> frequencyAny range <strong>with</strong>in the limits shownSpan range Zero range Resolution0 to 9.999Hz 0 to 9.998Hz 0.001Hz0 to 99.99Hz 0 to 99.98Hz 0.01Hz0 to 999.9Hz 0 to 999.8Hz 0.1Hz0 to 9999Hz 0 to 9998Hz 1HzNominally 12 Vdc (to 25 mA) – others on request (/FPS option)50 mVac to 250 Vac or 3 Vdc to 250 VdcAC or DC powered100 – 132 Vac (47–63Hz) or 200 – 264 Vac (47–63Hz)24 Vdc ±10% (others on request)AC 6VA or 6W at 24VdcNPN open collector transistor typeSwitched to 0 V when “on“to 200mA “on“ state currentor 50 Vdc “off“ state voltageNote: back–emf protection must be used for inductive loadsCommon negative railSPDT relay contacts3A at 240Vac (resistive)3A at 24Vdc (resistive)1kV between channels220mS (10–90mS, df=1)With analogue output fi ttedWith alarm channels three and four fi ttedCustom input sensor supply voltage. State voltage, e.g.,<strong>PMX400</strong>HZX/.../FPS/24VdcConnectionsTerminal Signal1 Neutral / −2 Live / +3 Output +4 Ouput −5 Common6 Channel 17 Channel 28 Security LinkPower supplyAnalogue output(/AO option only)Alarm Channel OneandAlarm Channel Two9 Pull up/downInputs/Security link10 Signal − / 0 VLink 12 & 8 for set-up11 Signal +mode (otherwise leavedisconnected)12 +12Vdc outSee user manual for full explanation of input connections13 Normally Closed14 CommonAlarm Channel Three(/RO option only)15 Normally Open16 Normally Closed17 CommonAlarm Channel <strong>Four</strong>(/RO option only)18 Normally OpenOrdering InformationType(Model Supply/Options)Cat. No.<strong>PMX400</strong>HZX 24Vdc 7940015595<strong>PMX400</strong>HZX 24Vdc/RO/AO 7940011979For other ranges please specify <strong>PMX400</strong>HZX 1/2 where:1 = Supply and 2 = OptionsPage 4 Subject to technical alterations <strong>with</strong>out notice • Printed in Australia • 7940015660 • 05/05/2009