Proline Promass 83E/F/O Modbus RS485 Operating Instructions

Proline Promass 83E/F/O Modbus RS485 Operating Instructions

Proline Promass 83E/F/O Modbus RS485 Operating Instructions

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Commissioning<strong>Proline</strong> <strong>Promass</strong> 83 <strong>Modbus</strong> <strong>RS485</strong>Brixgrade (density of hydrous saccharose solution in kg/m 3 )°Brix 10°C 20°C 30°C 40°C 50°C 60°C 70°C 80°C50 1233.87 1229.64 1224.98 1219.93 1214.50 1208.70 1202.56 1196.1155 1262.11 1257.64 1252.79 1247.59 1242.05 1236.18 1229.98 1223.5360 1291.31 1286.61 1281.59 1276.25 1270.61 1264.67 1258.45 1251.8865 1321.46 1316.56 1311.38 1305.93 1300.21 1294.21 1287.96 1281.5270 1352.55 1347.49 1342.18 1336.63 1330.84 1324.80 1318.55 1312.1375 1384.58 1379.38 1373.88 1368.36 1362.52 1356.46 1350.21 1343.8380 1417.50 1412.20 1406.70 1401.10 1395.20 1389.20 1383.00 1376.6085 1451.30 1445.90 1440.80 1434.80 1429.00 1422.90 1416.80 1410.50Source: A. & L. Emmerich, Technical University of Brunswick; officially recommended by ICUMSA, 20th session 1990Concentration measurement with flexible calculation functionUnder certain application conditions, it may not be possible to use density functions with a fixedcalculation function (% mass, °Brix, etc). However, user-specific or application-specificconcentration calculations can be used with the "FLEXIBLE" setting in the function DENSITYFUNCTION (7000).The following types of calculation can be selected in function MODE (7021):• % MASS 3D• % VOLUME 3D• % MASS 2D• % VOLUME 2DCalculation type "% MASS 3D" or "% VOLUME 3D"For this type of calculation, the relationship between the three variables – concentration, densityand temperature must be known (3-dimensional), e.g. by a table. In this way, the concentration canbe calculated from the measured density and temperature values by means of the following formula(the coefficients A0, A1, etc. have to be determined by the user):K=A0+A1· +A2· 2 +A3· 3 +A4· 4 +B1·T+B2·T 2 +B3·T3K Concentration Currently measured densityA0 Value from function (COEFFICIENT A0 (7032))A1 Value from function (COEFFICIENT A1 (7033))A2 Value from function (COEFFICIENT A2 (7034))A3 Value from function (COEFFICIENT A3 (7035))A4 Value from function (COEFFICIENT A4 (7036))B1 Value from function (COEFFICIENT B1 (7037))B2 Value from function (COEFFICIENT B2 (7038))B3 Value from function (COEFFICIENT B3 (7039))T Currently measured temperature in °Ca0004620Page 76 • MN0M030Issue/Rev. 0.2 (12/12)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!