Proline Promass 83E/F/O Modbus RS485 Operating Instructions
Proline Promass 83E/F/O Modbus RS485 Operating Instructions
Proline Promass 83E/F/O Modbus RS485 Operating Instructions
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Proline</strong> <strong>Promass</strong> 83 <strong>Modbus</strong> <strong>RS485</strong>CommissioningFig. 48:Selecting and configuring different density functions in the function matrixBrixgrade (density of hydrous saccharose solution in kg/m 3 )°Brix 10°C 20°C 30°C 40°C 50°C 60°C 70°C 80°C0 999.70 998.20 995.64 992.21 988.03 983.19 977.76 971.785 1019.56 1017.79 1015.03 1011.44 1007.14 1002.20 996.70 989.6510 1040.15 1038.10 1035.13 1031.38 1026.96 1021.93 1016.34 1010.2315 1061.48 1059.15 1055.97 1052.08 1047.51 1042.39 1036.72 1030.5520 1083.58 1080.97 1077.58 1073.50 1068.83 1063.60 1057.85 1051.6325 1106.47 1103.59 1099.98 1095.74 1090.94 1085.61 1079.78 1073.5030 1130.19 1127.03 1123.20 1118.80 1113.86 1108.44 1102.54 1096.2135 1154.76 1151.33 1147.58 1142.71 1137.65 1132.13 1126.16 1119.7940 1180.22 1176.51 1172.25 1167.52 1162.33 1156.71 1150.68 1144.2745 1206.58 1202.61 1198.15 1193.25 1187.94 1182.23 1176.14 1169.70Issue/Rev. 0.2 (12/12) MN0M030 • Page 75