Commissioning<strong>Proline</strong> <strong>Promass</strong> 83 <strong>Modbus</strong> <strong>RS485</strong>"Communication" Quick Setup.HOME position F MEASURAND O QUICK SETUP N QUICK SETUP COMMUNICATIONFunction No. Function name Setting to be selected ( OS )(to next function with F )1006 QUICK SETUPCOMMUNICATIONYES After F is pressed by way of confirmation, the Quick Setupmenu calls up all the subsequent functions in succession.6301 BUS ADDRESS Enter the device address (permitted address range: 1 to 247)Factory setting: 2476302 BAUDRATE Supported baudrates [BAUD]:1200/2400/4800/9600/19200/38400/57600/115200Factory setting: 19200 BAUD6303 MODEDATA TRANSFERSelect the data transfer mode:•ASCII Data transmission in the form of readable ASCIIcharacters. Error protection via LRC.• RTU Data transmission in binary form.Error protection via CRC16.Factory setting: RTU6304 PARITY Selection depends on the "Data transfer mode" function:NONE; EVEN; UNEVEN• Available in the ASCII transfer mode even or uneven parity bit(EVEN, UNEVEN).• Available in the RTU transfer mode no parity bit (NONE) or evenor uneven parity bit (EVEN, UNEVEN).Factory setting: EVEN6305 BYTE SEQUENCE Select the byte transmission sequence for the Integer, Float and Stringdata types:0 - 1 - 2 - 33 - 2 - 1 - 02 - 3 - 0 - 11 - 0 - 3 - 2Factory setting: 1 - 0 - 3 - 2! Note!The transmission sequence must suit the <strong>Modbus</strong> master.6306 RESPONSE TELEGRAMDELAYFor entering a delay time after which the measuring device replies tothe request telegram of the <strong>Modbus</strong> master. This allowscommunication to be adapted to slow <strong>Modbus</strong> masters:0 to 100 msFactory setting: 10 msBack to the HOME position: Press and hold down Esc keys X for longer than three seconds or Repeatedly press and release Esc keys X = Exit the function matrix step by step!Note!The parameters described in the table can be found in the "<strong>Modbus</strong> <strong>RS485</strong>" group of the "BASICFUNCTION" block in the function matrix (see separate "Description of Device Functions" manual).Page 72 • MN0M030Issue/Rev. 0.2 (12/12)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!