10.07.2015 Views

Proline Promass 83E/F/O Modbus RS485 Operating Instructions

Proline Promass 83E/F/O Modbus RS485 Operating Instructions

Proline Promass 83E/F/O Modbus RS485 Operating Instructions

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Operation<strong>Proline</strong> <strong>Promass</strong> 83 <strong>Modbus</strong> <strong>RS485</strong>Scan listNo.<strong>Modbus</strong> configurationRegister address(data type = Integer)Configuration vialocal operation / configuration program(BASIC FUNCTION <strong>Modbus</strong> <strong>RS485</strong> )13 5013 SCAN LIST REG. 1314 5014 SCAN LIST REG. 1415 5015 SCAN LIST REG. 1516 5016 SCAN LIST REG. 16Access to data via <strong>Modbus</strong>The <strong>Modbus</strong> master uses the register addresses 5051 to 5081 to access the data area of the autoscanbuffer. This data area contains the values of the device parameters defined in the scan list. Forexample, if the register 2007 was entered for mass flow in the scan list by means of the SCAN LISTREG. 1 function, the master can read out the current measured value of the mass flow inregister 5051.Data areaParameter value/Measured valuesAccess via <strong>Modbus</strong>register addressData type *Access**Value of scan list entry No. 1 5051 Integer / Float Read / WriteValue of scan list entry No. 2 5053 Integer / Float Read / WriteValue of scan list entry No. 3 5055 Integer / Float Read / WriteValue of scan list entry No. 4 5057 Integer / Float Read / WriteValue of scan list entry No. 5 5059 Integer / Float Read / WriteValue of scan list entry No. 6 5061 Integer / Float Read / WriteValue of scan list entry No. 7 5063 Integer / Float Read / WriteValue of scan list entry No. 8 5065 Integer / Float Read / WriteValue of scan list entry No. 9 5067 Integer / Float Read / WriteValue of scan list entry No. 10 5069 Integer / Float Read / WriteValue of scan list entry No. 11 5071 Integer / Float Read / WriteValue of scan list entry No. 12 5073 Integer / Float Read / WriteValue of scan list entry No. 13 5075 Integer / Float Read / WriteValue of scan list entry No. 14 5077 Integer / Float Read / WriteValue of scan list entry No. 15 5079 Integer / Float Read / WriteValue of scan list entry No. 16 5081 Integer / Float Read / Write* The data type depends on the device parameter entered in the scan list** The data access depends on the device parameter entered in the scan list. If the device parameter entered supportsread and write access, the parameter can also be accessed by means of the data area.Page 50 • MN0M030Issue/Rev. 0.2 (12/12)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!