10.07.2015 Views

Proline Promass 83E/F/O Modbus RS485 Operating Instructions

Proline Promass 83E/F/O Modbus RS485 Operating Instructions

Proline Promass 83E/F/O Modbus RS485 Operating Instructions

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Installation<strong>Proline</strong> <strong>Promass</strong> 83 <strong>Modbus</strong> <strong>RS485</strong>BCAFig. 13:<strong>Promass</strong> I, mounted with mounting clampA0010008DN 8 15 15FB 25 25FB 40 40FB 50 50FB 50FB 80 80Tri-Clamp ½" 3/4" 1" 1" 1 ½" 1 ½" 2" 2" 2 ½" 3" 2 ½" 3"A 373 409 539 539 668 668 780 780 1152 1152 1152 1152B 20 20 30 30 28 28 35 35 57 57 57 57C 40 40 44.5 44.5 60 60 80 80 90 90 90 90"Caution!3.2.5 HeatingSome fluids require suitable measures to avoid loss of heat at the sensor. Heating can be electric,e.g. with heated elements, or by means of hot water or steam pipes made of copper or heatingjackets.• Risk of electronics overheating! Make sure that the maximum permissible ambient temperaturefor the transmitter is not exceeded. Consequently, make sure that the adapter between sensor andtransmitter and the connection housing of the remote version always remain free of insulatingmaterial. Note that a certain orientation might be required, depending on the fluid temperatureä 16. For fluid temperature of 150°C (302°F) or above the usage of the remote version withseparate connection housing is recommended.• With a fluid temperature between 200 °C to 350 °C (392 to 662 °F) the remote version of thehigh-temperature version is preferable.• When using electrical heat tracing whose heat is regulated using phase control or by pulse packs,it cannot be ruled out that the measured values are influenced by magnetic fields which mayoccur, (i.e. at values greater than those permitted by the EC standard (Sinus 30 A/m)). In suchcases, the sensor must be magnetically shielded.The secondary containment can be shielded with tin plates or electric sheets without privilegeddirection (e.g. V330-35A) with the following properties:– Relative magnetic permeability r 300– Plate thickness d 0.35 mm (0.014")• Information on permissible temperature ranges ä 134• <strong>Promass</strong> X: Especially under critical climatic conditions it has to be ensured that the temperaturedifference between environment and measured medium does not exceed 100 K. Suitablemeasures, such as heating or thermal insulation, are to be taken.Special heating jackets which can be ordered as accessories from are available forthe sensors.Page 20 • MN0M030Issue/Rev. 0.2 (12/12)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!