10.07.2015 Views

Proline Promass 83E/F/O Modbus RS485 Operating Instructions

Proline Promass 83E/F/O Modbus RS485 Operating Instructions

Proline Promass 83E/F/O Modbus RS485 Operating Instructions

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Proline</strong> <strong>Promass</strong> 83 <strong>Modbus</strong> <strong>RS485</strong>Technical dataPressure loss formulas for <strong>Promass</strong> AReynolds number4·gRe = ·d· · a0003381Re 2300 1)0.25 1.75 –0.75p=K· · g · a0003380Re < 2300p=K1· ·ga0003379p = pressure loss [mbar] = kinematic viscosity [m 2 /s]g = mass flow [kg/s] = density [kg/m ]d = inside diameter of measuring tubes [m]K to K1 = constants (depending on nominal diameter)1)To compute the pressure loss for gases, always use the formula for Re 2300.Pressure loss formulas for <strong>Promass</strong> O, XReynolds numberPressure lossp = pressure loss [mbar] = kinematic viscosity [m 2 /s]g = mass flow [kg/s] = density [kg/m 3 ]4 gRe = d n1( )A 1/A 2 g2 3p = (A 0 + A1Re ) 5 n dd = inside diameter of measuring tubes [m]A to A = constants (depending on nominal diameter)n = number of tubes22A0015582A0015583Issue/Rev. 0.2 (12/12) MN0M030 • Page 137