Technical data<strong>Proline</strong> <strong>Promass</strong> 83 <strong>Modbus</strong> <strong>RS485</strong>Measuring ranges for gases (<strong>Promass</strong> A)DNx[mm][inch]1 1/24 322 1/12 324 1/8 32Measuring ranges for gases (<strong>Promass</strong> I)DNx[mm][inch]8 3/8 6015 ½ 8015 FB ½ FB 9025 1 9025 FB 1 FB 9040 1 ½ 9040 FB 1 ½ FB 9050 2 9050 FB 2 FB 11080 3 110FB = Full bore versions of <strong>Promass</strong> IMeasuring ranges for gases (<strong>Promass</strong> X)DNx[mm][inch]350 14 200Calculation example for gas:• Sensor type: <strong>Promass</strong> F, DN 50• Gas: air with a density of 60.3 kg/m³ (at 20 °C and 50 bar)• Measuring range (liquid): 70000 kg/h• x = 90 (for <strong>Promass</strong> F DN 50)Max. possible full scale value:g max(G) = g max(F) · (G) ÷ x [kg/m³] = 70000 kg/h · 60.3 kg/m³ ÷ 90 kg/m³ = 46900 kg/hRecommended full scale valuesSee Page 127 ff. ("Limiting flow")Operable flow rangeGreater than 1 000 : 1. Flows above the preset full scale value do not overload the amplifier, i.e.totalizer values are registered correctly.Page 110 • MN0M030Issue/Rev. 0.2 (12/12)
<strong>Proline</strong> <strong>Promass</strong> 83 <strong>Modbus</strong> <strong>RS485</strong>Technical dataInput signalStatus input (auxiliary input):U = 3 to 30 V DC, R i = 3 k, galvanically isolated.Switch level: ±3 to ±30 VDC, independent of polarityStatus input (auxiliary input):U = 3 to 30 V DC, R i = 3 k, galvanically isolated.Switch level: 3 to 30 V DC, independent of polarity.Configurable for: totalizer reset, positive zero return, error message reset, zero point adjustmentstart.10.1.4 OutputOutput signalCurrent outputActive/passive selectable, galvanically isolated, time constant selectable (0.05 to 100 s),full scale value selectable, temperature coefficient: typically 0.005% o.f.s/°C, resolution: 0.5 A• Active: 0/4 to 20 mA, R L < 700 • Passive: 4 to 20 mA; supply voltage U S 18 to 30 V DC; R i 150 Pulse / frequency output:Active/passive selectable, galvanically isolated• Active: 24 V DC, 25 mA (max. 250 mA during 20 ms), R L > 100 • Passive: open collector, 30 V DC, 250 mA• Frequency output: full scale frequency 2 to 10000 Hz (f max = 12500 Hz), on/off ratio 1:1, pulsewidth max. 2 s• Pulse output: pulse value and pulse polarity selectable, pulse width configurable (0.05 to2000 ms)<strong>Modbus</strong> <strong>RS485</strong>:• <strong>Modbus</strong> device type: slave• Address range: 1 to 247• Functions codes supported: 03, 04, 06, 08, 16, 23• Broadcast: supported with the function codes 06, 16, 23• Physical interface: <strong>RS485</strong> in accordance with standard EIA/TIA-485• Baudrate supported: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 Baud• Transmission mode: RTU or ASCII• Response time:Direct data access = typically 25 to 50 msAuto-scan buffer (data area) = typically 3 to 5 ms• Possible output combinations ä 31Signal on alarmCurrent outputFailsafe mode selectable (for example NAMUR recommendation NE 43)Pulse/frequency outputFailsafe mode selectableRelay outputDe-energized by fault or power supply failure<strong>Modbus</strong> <strong>RS485</strong>If an error occurs, the value NaN (not a number) is output for the process variables.Issue/Rev. 0.2 (12/12) MN0M030 • Page 111