10.07.2015 Views

Download the Catalog Data-Sheet PDF - LiveWire Electrical Supply

Download the Catalog Data-Sheet PDF - LiveWire Electrical Supply

Download the Catalog Data-Sheet PDF - LiveWire Electrical Supply

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Full Voltage Reversing Starters—NEMA RatedClass 8736jFI SQUARE Dwww.SquareD.comFor <strong>the</strong> most up-to-date information3-Pole Polyphase—600 Vac Maximum—50-60 HzClass 8736 Type S reversing magnetic starters are used for full-voltage starting, stopping, and reversing AC squirrel cagemotors. Class 8736 starters consist of one Class 8502 contactor and one Class 8536 starter mechanically andelectrically interlocked. Open type devices, Sizes 0-5, are available in ei<strong>the</strong>r horizontal or vertical arrangements. Sizes00, 6, and 7 are available as horizontal only. Enclosed devices use horizontally arranged components. Type S startersare designed for operation at 600 Vac, 50-60 Hz.NEMA Sizes 00, 0,1Reversing StarterOverload RelaysClass 8736 Type S Size 00-6 reversing starters are provided with melting alloy <strong>the</strong>rmal overload relay as standard.Interchangeable <strong>the</strong>rmal units are available in standard trip Sizes 00-6, as are bimetallic overload relays. Ambientcompensated and non-compensated versions are supplied with manual or automatic reset, trip current adjustment, andan alarm contact on Sizes 0-2.Quick trip is available on Sizes 00-4, and slow trip on Sizes 00-3. Solid State Overload Relays are also available forNEMA Sizes 0-4.Single phase starters use one <strong>the</strong>rmal unit; three phase starters use three <strong>the</strong>rmal units. See page 14-129 for selectioninformation.Solid State Overload Relay Protection (MOTOR LOGIC®)These ambient insensitive overload relays are available on sizes 00 through 6 and standard on size 7. They provide phaseloss, phase unbalance protection and a power LED indication. To order, add Form H10 (for Class 10), H20 (for Class 20),or H30 (for selectable trip class protection). For more information about MOTOR LOGIC overload relays, see page 14-97.jj0001234567ContinuousCurrent Ratings918274590135270540810MotorVoltage200230460575Separate (200230460575Separate C200230460575Separate (200230460575Separate C;ontrol»200 150230 200460 400575 400Separate C;ontrol«200230460575Max.HPSeparate (!k>ntrol«200230460575iVa1'/222Separate < Control*200 3230 3 SBO10*46057555Separate ( Control »2002304605757%7'/ 21010SCO7*Separate ( Jontrol*10152525Control*25305050Control*4050100100Control*75100200200300600600VerticalTypeSDO1*SEO1*SFO1*SGO1*Open TypeHorizontalTypeSAO16*SBO4*SCO8*SDO2*SEO2*SFO3+SJO1*Price$ 617.731.827.1566. SDG2*2601.NEMA1General PurposeEnclosureTypeSAG 16* $ 659.SBG4*SCG8*SEG2*6353. SFG3*40833. SJG1*Price773.887.1722.2871.6849.45584.NEMAType 4 & 4XWatertight, DusttlghtBrushedStainless SteelEnclosure(Sizes 0-5)iTypeSBW14*SCW14*SDW11*SEW11*SFW11*SGO3* 12206. SGG3* 15068. SGW11*SHO1* 28803. SHG1* 33554. SHW1*SJW1*Use Size 0Price$ 1209. SBT49* $2529. SBR9* $3161. SBA4* $ 944.1494.9432.17156.38301.50331.NEMA 7 & 9Hazardous LocationsClass 1, Groups C & DClass II, Groups E, F & GBoltedTypePriceUse Size 0SPIN-TOP*Type4334. SET43* 7115. SER3*PriceUse Size 0SCT49* 2652. SCR9* 3317. SCA4*2709. SDT43* 4428. SOR3* 5376. SDA1*NEMAType 12Dusttight &DriptlghtIndustrial UseEnclosure •Type8895. SEA1*PriceUse Size 0SFA1*SGA1* 17156.SHA1* 36117.A NEMA 4 & 4X stainless steel enclosures (sizes 0-5) have a brushed finish; for an electropolished finish, specify Form G16 and add 15% to <strong>the</strong> price of <strong>the</strong>standard device. Sizes 6 & 7 are painted sheet steel and are rated NEMA 4 only.• NEMA 12 devices are available UL Listed for use in Class II, Division 2, Group G and Class III, Divisions 1 and 2 locations. Request Form G21, no charge,# 120 Volt polyphase contactors are wired for separate control and must be ordered with Form S (i.e., 8736SCO8V02S).* Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown on page 14-51.SJA1*1058.2007.3498.7818.48147.For additional information, reference <strong>Catalog</strong> #8502CT9701.14-50CP1DiscountSchedule© 2003 Schneider ElectricAll Rights Reserved9/8/03


If] I SQUARE Dwww.SquareD.comFor <strong>the</strong> most up-to-date informationFull Voltage Reversing Starters—NEMA RatedClass 8736600 Vac Maximum—50-60 HzNote that prices shown do not include <strong>the</strong>rmal units. Standard trip <strong>the</strong>rmal units are $14.30 each. See page 14-129 for selection information.NEMASizeContinuousCurrentMotorVoltageMax.HpIE?2-Pole Single Phase—1 Thermal Unit Required0001g1827115230115230115230V 31Single2Phase3-Wire23VerticalTypeSBO7BSC01"3-Pole Single Phase—1 Thermal Unit Required000191827115230115230115230115230115230115230V 3 1 /3121223234- WireRep.-lnd.4-WlreSplit Ph.4-WireRep.-lnd.4-WireSplit Ph.4- WireRep.lnd.4-WireSplit Ph.4-Pole Polyphase—2 Thermal Units Required0123418274590135Separate ControU2002304605753355Separate Control A2002304605757V 27V 21010Separate ControU20023046057510152525Separate ControU20023046057525305050Separate Control A20023046057540501001002 Phase4-WireSB08ISB09*SCO3"SCO5ISBO11"SCO9"Open TypeHorizontalTypeSAO13BSB01BSC02BSA014ISAO15"SB02«SBO3"SCO4«SCO6"SBOSlSCO10"SOO4"SEO4"SFO4"Price$ 575.689.783.594.594.708.708.803.803.921.1044.1965.3257.8138.NEMA1General PurposeEnclosureTypeSAG13HSBGHSCG2BSAG14BSAG15BSBG2*SBG3ISCG4ISCG6ISBG5BSCG10»SDG4ISEG4«SFG4"PriceS 615.* 120 Volt starters are wired for separate control and must be ordered with Form S (i.e., 8736SBO7V02S).• Coil voltage code must be specified to order this product. Refer to standard coil voltage codes shown below.Coil Voltage Codes60 Hz24* «120*208240480600SpecifyVoltage50 Hzlib220440550SpecifyCodeV01V02V08V03V06V07V99729.843.635.635.749.749.863.863.962.1086.2121.3545.8654.Price AdderNo ChargeNo ChargeNo CharQGNo ChargeNo ChargeNo Charge$23.70* 24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V coils are available, Form S(separate control) must be specified (i.e., order as 8736SCO1U01 S).* <strong>the</strong>se voltage codes must include Form S (supplied at no charge) (i.e., order as 8736SBO7V02S).Note: For voltage codes used with control transformers, see page 14-110.Form S (separate control) is used when a separate source of power is available for <strong>the</strong> control (coil) voltage.Form S is supplied at no charge.NEMA4&4XWatertight,DusWghtBrushed StainlessSteel EnclosureTypeUse Size 0SBW11ISCW11"Use Size 0Use Size 0SBW12BSBW13«SCW12"SCW13"SBW15ISCW15"SDW12"SEW12"SFW12"Price$1167.1451.1185.1185.1470.1470.1400.1694.3165.4988.11255.BoltedTypeHazardous LocationsClass 1, Groups C & DClass II, Groups E, F & GUse Size 0SBT46*SCT461Use Size 0Use Size 0SBT47"S8T48"SCT47BSCT48"Price$2481.2606.2501.2501.2628.2628.Contact your nearestSquare D/SchneiderElectric sales office.ContactyournearestSquare D/SchneiderElectric sales office.ContactyournearestSquare D/SchneiderElectric sales office.SPIN TOP*TypeUse Size 0SBR61SCR6ISBR7BSBR8>SCR7BSCR8BUse Size 0Use Size 0SBR10ISCR10"SDR4«Price$3104.3255.3128.3128.3288.3288.3422.3597.6165.NEMA 12Dusttight &DrlptightIndustrial UseEnclosureTypeUse Size 0SBA1«SCA1«Use Size 0Use Size 0SBA2ISBA3ISCA2ISCA3»SBA5"SCA5«SDA2"SEA2ISFA2"Price$ 900.1014.920.920.1034.1034.1133.1257.2406.4152.9641.DimensionsFactory Modifications (Forms) ....Separate Enclosures (Class 9991).Replacement Parts (Class 9998) ..Type S Accessories (Class 9999)..page 14-52page 14-109page 14-102page 14-118page 14-121For additional information, reference <strong>Catalog</strong> #8502CT9701.©2003 Schneider ElectricAll Rights Reserved9/8/03CP1DiscountSchedule 14-51


Factory Modifications (Forms)For Full Voltage Contactors and Starters(111 SQUARE E)www.SquareD.comFor <strong>the</strong> most up-to-date informationFull Voltage Controllers OnlyClasses 8502, 8536, 8538, 8539, 8702, 8736, 8738, 8739, 881 0, 881 1 and 881 2Factory ModificationsEnclosureTypeForm00012NEMA SIZE34567CONTROLCIRCUITFull VoltageandMulti-SpeedControllersOnlyClasses850285368538^m 8539• 8702T, 8736- 87381T8739! 8810^ 8811• 881251Separate Control Circuit — (specifyFused Control Circuit(without control transformer)Two fusesControl Circuit Transformers"Standard capacity (50 or 60 Hz)NOTE: All orders requesting Form FTwill be supplied as Form F4T.FUSESPrimary Secondary2 02 01 10 . . . .2 12 1 . . . .1 202 2Additional Capacity (50 or 60 Hz)Two fuses in primary1 00 VA additional capacity200 VA additional capacityTwo fuses in primary and one fuse in secondary1 00 VA additional capacity ...100 VA additional capacity200 VA additional capacity300 VA additional capacity ... .400 VA additional capacity500 VA additional capacity. ... ...Substitute dual-voltage magnet coil.Any1.3R, 4, 4X, 121,3R,4,4X,7,9,121,4, 4X, 127&91,4, 4X, 121,4, 4X, 127&91,4, 4X, 121,4, 4X, 121,4,4X, 127&91,4,4X, 121,4,4X, 127&91.4. 4X, 121,4, 4X, 121,4, 4X, 121.4, 4X, 12AnyA All combination style devices such as 8538.8539,8738,8739, that use Form S should alsouse Form Y74 (auxiliary contact installed on disconnect switch) per NEC Article 430-74.• Table at right.4 Single primary voltage must be specified.* Not available on Size 2 or Size 3 devices with 4- or 5-poles.T Not available on this Size. Select appropriate transformer with secondary fuse protection.A Not available with 24 V secondary on Size 3. Select appropriate transformer with secondaryfuse protection. See Table at right for 24 V secondary restrictions.D Not available with 24 V secondary. Select appropriate transformer with secondary fuseprotection. See Table at right for 24 V secondary restrictions.| 0 Single phase with one leg grounded or grounded B phase applications ONLY.Marine ControlClass8502853685388539870287368738873988108941FormM10FactoryModificationModification of standard device for useas marine control per UL508OOv Ov 1$225.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!