20.11.2012 Views

BDâ„¢ P700 Blood Collection System for Plasma GLP-1 Preservation

BDâ„¢ P700 Blood Collection System for Plasma GLP-1 Preservation

BDâ„¢ P700 Blood Collection System for Plasma GLP-1 Preservation

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

BD <strong>P700</strong><br />

<strong>Blood</strong> <strong>Collection</strong> <strong>System</strong> <strong>for</strong><br />

<strong>Plasma</strong> <strong>GLP</strong>-1 <strong>Preservation</strong><br />

BD <strong>P700</strong> is <strong>for</strong> Research Use Only — Not <strong>for</strong> Use in Diagnostic Procedures<br />

Preserve<br />

www.bd.com/proteomics


BD <strong>P700</strong> <strong>Blood</strong> <strong>Collection</strong> <strong>System</strong><br />

<strong>for</strong> <strong>Plasma</strong> <strong>GLP</strong>-1 <strong>Preservation</strong><br />

Studies show that BD <strong>P700</strong> enables<br />

significant increase in <strong>GLP</strong>-1 recovery (Table 1).<br />

BD <strong>P700</strong> is a new protein preservation blood<br />

collection tube that contains a proprietary Dipeptidyl<br />

Peptidase IV (DPP-IV) protease inhibitor. The tube<br />

is especially suited as the blood collection tube<br />

of choice <strong>for</strong> assays that require quantitation and<br />

measurement of the preproglucagon-derived glucose<br />

regulatory peptide, glucagon-like peptide 1 (<strong>GLP</strong>-1).<br />

Tube Size 13 x 75 mm plastic tube<br />

Draw Volume 3 mL<br />

Closure translucent lavender BD Hemogard shield<br />

Separator none<br />

Sterilization Sterility Assurance Level (SAL) 10 -6<br />

Anticoagulant 5.4 mg K 2 EDTA (spray coated)<br />

Additive<br />

BD <strong>P700</strong> <strong>Blood</strong> <strong>Collection</strong> Tube Specifications<br />

Storage 2 – 8° C<br />

proprietary Dipeptidyl Peptidase IV (DPP-IV)<br />

inhibitor (lyophilized)<br />

Expire 1 year from date of manufacture


Table 1. Comparison of plasma <strong>GLP</strong>-1 levels obtained from whole blood samples<br />

collected into BD <strong>P700</strong> and K 2 EDTA Tubes. <strong>Blood</strong> was drawn directly from<br />

12 subjects into BD <strong>P700</strong> and K 2 EDTA evacuated tubes at room temperature.<br />

<strong>GLP</strong>-1 was measured using a <strong>GLP</strong>-1 (7-36)-Amide competitive enzyme immunoassay.<br />

BD <br />

<strong>P700</strong><br />

<strong>GLP</strong>-1<br />

(pM/mL)<br />

BD <strong>P700</strong> Enhances <strong>Preservation</strong><br />

of <strong>GLP</strong>-1 (7-36)-Amide *<br />

BD <strong>P700</strong> versus EDTA <strong>Plasma</strong><br />

BD <strong>P700</strong> K 2 EDTA<br />

Mean 2.5 1.1<br />

Standard Deviation 3.4 1.8<br />

Minimum 0 0<br />

Maximum 10.2 4.3<br />

Total Subjects 12 12<br />

BD <strong>P700</strong>: Standard Electrolyte<br />

and Chemistry 8 Profile Analysis *<br />

Sodium<br />

(nmol/L)<br />

Chloride<br />

(nmol/L)<br />

BD <strong>P700</strong> versus EDTA <strong>Plasma</strong><br />

HCO3 (nmol/L)<br />

BUN<br />

(mg/dL)<br />

Creatinine<br />

(mg/dL)<br />

Glucose<br />

(mg/dL)<br />

Total Protein<br />

(g/dL)<br />

Albumin<br />

(g/dL)<br />

Table 2. Comparison of plasma electrolyte and Chemistry 8 profile <strong>for</strong> whole blood<br />

samples collected into BD <strong>P700</strong> and K 2 EDTA Tubes. <strong>Blood</strong> was drawn directly<br />

from 12 subjects into BD <strong>P700</strong> and K 2 EDTA evacuated tubes at room temperature.<br />

An aliquot of each plasma sample was prepared <strong>for</strong> use in Standard Electrolyte and Chemistry<br />

8 Profile analyses. Comparable quantitation of analytes were observed using BD <strong>P700</strong><br />

and K 2 EDTA Tubes.<br />

* Based on studies using 12 samples; cannot be guaranteed to be statistically valid.<br />

Bilirubin<br />

(mg/dL)<br />

ALT<br />

(U/L)<br />

AST<br />

(U/L)<br />

147.3 99.5 16.5 15.2 0.9 101.5 7.5 4.6 0.5 21.2 25.8<br />

SD 3.8 2.2 2.1 3.4 0.2 18.1 0.4 0.3 0.5 7.4 4.9<br />

K 2 EDTA 140.5 97.3 17.9 15.2 0.8 101.2 7.5 4.5 0.5 23.4 23.8<br />

SD 2.2 2.6 2.0 3.1 0.2 19.1 0.3 0.3 0.5 11.1 5.5


Reference<br />

Number<br />

Kit Contents<br />

20<br />

BD <strong>P700</strong> Product Description<br />

366473<br />

BD <strong>P700</strong> <strong>Blood</strong> <strong>Collection</strong> Tubes<br />

Ten (10) tubes/foil pouch, Two (2) foil pouches/box with desiccant<br />

1 Product Instructions<br />

1 “Research Use Only” Certification Card<br />

Required Accessories **<br />

Description Reference Number<br />

BD Vacutainer ® Safety-Lok <strong>Blood</strong> <strong>Collection</strong> Set<br />

(21 G butterfly needle, 12" (304.8 mm) tubing:<br />

sterile, use once and discard)<br />

BD Vacutainer ® One Use Holder 364815<br />

Region Ordering Technical<br />

US<br />

† BD <strong>P700</strong> is sold directly by BD. Not available through distributors.<br />

** Product must be used with a 12" blood collection set, such as BD Vacutainer ® Safety-Lok <strong>Blood</strong> <strong>Collection</strong> Set.<br />

BD, BD Logo and all other trademarks are property of<br />

Becton, Dickinson and Company. © 2008 BD 06/08 VS7641-2<br />

367281 (North America)<br />

367286 (Outside North America)<br />

Ordering and Technical In<strong>for</strong>mation †<br />

888.237.2762 (phone orders)<br />

800.847.2220 (fax orders)<br />

800.631.0174 (phone)<br />

vacutainer_techservices@bd.com<br />

(email)<br />

Canada 800.268.5430 ext. 5567 800.268.5430 ext. 5567<br />

All other areas Please visit www.bd.com to locate your regional office<br />

1 Becton Drive<br />

Franklin Lakes, NJ 07417<br />

www.bd.com/proteomics

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!